Sourcetronic ST2883 Series Скачать руководство пользователя страница 1

ST2883 Series Operation Manual                                                          

 

Operation

 

Manual

 

 

  

MODEL

 

ST2883

5/

10

 

 

  

Impulse

 

Winding

 

Tester

 

 

  

 

  

 

  

 

  

 

S

SS

o

oo

u

uu

r

rr

c

cc

e

ee

t

tt

r

rr

o

oo

n

nn

i

ii

c

cc

 

  

G

G

G

m

m

m

b

bb

H

H

H

 

 

  

Fahrenheitstraße

 

1

 

28359

 

Bremen

 

Germany

 

 

  

TEL

+49

 

421

 

2779999

 

 

  

FAX

+49

 

421

 

2779998

 

 

  

[email protected]

 

 

  

www.sourcetronic.com

 

Содержание ST2883 Series

Страница 1: ...ual MODEL ST2883 5 10 Impulse Winding Tester S S So o ou u ur r rc c ce e et t tr r ro o on n ni iic c c G G Gm m mb b bH H H Fahrenheitstra e 1 28359 Bremen Germany TEL 49 421 2779999 FAX 49 421 2779...

Страница 2: ...panel 3 1 3 2 Rear panel 3 3 3 3 Introduction to display area 3 4 Chapter 4 Introduction to DISP 4 1 4 1 Measurement display page 4 1 4 2 Introduction to symbols in measurement display page 4 1 4 3 I...

Страница 3: ...3 6 1 10 Date 6 3 6 1 11 Time 6 3 6 2 Interface 6 4 6 2 1 I O 6 4 6 2 2 ST2883 RS232C interface 6 4 6 2 3 USB interface 6 6 6 2 4 LAN interface 6 9 6 3 About 6 11 Chapter 7 User guide 7 1 7 1 Use of k...

Страница 4: ...istic subsystem commands 8 18 8 4 9 TRIGger subsystem commands 8 19 8 4 10 FETCh subsystem commands 8 20 8 4 11 MEASure subsystem commands 8 21 8 4 12 ABORt subsystem command 8 22 8 4 13 Mass MEMory s...

Страница 5: ...f high voltage in instrument 6 Carry or move Before moving the instrument unplug the AC power sockets and remove high voltage test line or external control line 7 Maintenance In non use state the inst...

Страница 6: ...the differences in the number of turns and the material of the core If high impulse voltage is applied the poor insulation will appear as a corona or layer discharge Figure 1 1 Simplified diagram for...

Страница 7: ...rking temperature 20 C 8 C Humidity 80 RH Transferring environment temperature 0 C 50 C Humidity 93 RH 1 2 3 Warm up The warm up time should not be less than 15 minutes 1 3 Dimensions and weight Dimen...

Страница 8: ...40ns Resolution 8bits Sampling point 6000bytes Standard wave sample Sequential cycle single cycle one sample up to 32 times of sample averaging Input impedance 5M Test speed 6 times sec Averaging rate...

Страница 9: ...short circuit between layers the short circuit area is reflected as an increase of energy loss 2 2 2 Differential area comparison When comparison method is set to Differential Area ST2883 calculates t...

Страница 10: ...specify a zero crossing point to compare The instrument will judge the zero crossing offset between the tested waveform and standard waveform and then compare the oscillation period between the two wa...

Страница 11: ...e different functions in different menus Five soft keys are used to select control and parameter functions Current function of each soft key is displayed along its left side 4 DISP Press DISP menu key...

Страница 12: ...inals or DUT 13 PASS FAIL indicator When PASS indicator flashes the comparison result is up to standard while FAIL below indicator Valid only in comparison function 14 START Press the START key to sta...

Страница 13: ...control ST2883 through the USB DEVICE interface 3 RS232C serial interface RS232C serial interface can be connected to an external device for remote control and operation 4 LAN interface Be used to co...

Страница 14: ...t process STOP means the test has been terminated 3 Waveform display area In this area test and standard waveforms peaks of impulse voltage and comparison results are displayed 4 Indicate the waveform...

Страница 15: ...e of interface selecting availability of U disk key lock etc 13 Time base This area shows the time between the two dash lines of this waveform display area in X direction The time shown in this area c...

Страница 16: ...setting Compare measurement function Measure auxiliary function Utility statistic function Statistics display color of the waveform sampling rate etc Figure 4 1 shows the measurement display page 4 1...

Страница 17: ...plete Press this key to complete the acquisition of standard waveforms Average 1 Indicate the sampling times for standard waveform Undo Cancel the current acquisition data for standard waveform Each p...

Страница 18: ...nge an error information will prompt and the instrument will keep in the wait state to Start a new sample Start Start loop test Return to previous page 4 3 1 4 Modify Lighten the icon to enable the ro...

Страница 19: ...6000 Lighten the icon to enable the roller and change the differential value Return to previous page 4 3 2 2 DIFF ZONE Select the differential area size comparison method All setup operations are the...

Страница 20: ...and enable the roller Then revolve the roller to enlarge the waveform display scale ranging from 1 to 3 times When the display scale is larger than 1 times the ratio will be displayed in the top right...

Страница 21: ...oved by pressing START except in the measure display page NOTE When the icon is lightened the original numerical input function for the four numerical keys will be invalid Coarse adjustment key used t...

Страница 22: ...or to the sample rate zone following soft keys are available Be used to select the desired sample rate Lighten this key to enable the numerical arrow key Respectively press 8 2 4 6 the cursor will mov...

Страница 23: ...waveforms after each test and the test speed will be decreased ALL OFF With the exception of comparison result none waveforms will be displayed therefore the test speed is the fastest in this mode Li...

Страница 24: ...lly done by comparing with four comparison methods Move the cursor to this zone following soft keys will be displayed ON Turn BDV test on OFF Turn BDV test off Lighten this key to enable the numerical...

Страница 25: ...left and right 5 2 14 Position AREA SIZE DIFF ZONE PHASE DIFF Set the comparison ranges for AREA SIZE DIFF ZONE and CORONA that range from 0 to 6000 the value of the end position must be larger than t...

Страница 26: ...the limit values for comparison methods of CORONA which range from 0 to 256 by a resolution of 1 dot Use numeric buttons to enter the required value and press ENTER for confirmation Move the cursor t...

Страница 27: ...ess the Delete soft key and then choose YES to confirm this operation or NO to give up Note If the selected file has been loaded the starting up load function will be invalid Save Press this key to sa...

Страница 28: ...er name the folder will be named as the default name FOLDERxx xx is a number ranging from 01 to 99 Pressing ESC can exit the operation of creating Letters from A to Z numbers from 0 to 9 and underline...

Страница 29: ...ES otherwise NO Note Although the instrument supports three file formats STA TXT and CSV only STA file can be loaded to internal RAM Delete Delete saved files Press Delete Then choose YES to delete th...

Страница 30: ...gure 6 1 System Parameters irrelevant to test performance can be set in this page Brightness Pass Fail Pass Alarm Fail Alarm Key Sound Hard Copy Password Language Theme Date Time 6 1 1 Brightness Move...

Страница 31: ...press 8 2 4 6 the cursor will move up down left and right 6 1 5 Key Sound Move the cursor to this zone following soft keys will be displayed On Turn on the key sound Off Turn off the key sound Lighten...

Страница 32: ...ay format is like 2011 05 04 Move the cursor to this zone following soft keys can be used They are soft keys used to adjust date by 1 day Lighten this key to enable the numerical arrow key Respectivel...

Страница 33: ...ve in the corresponding zone For example when RS232C interface is selected the cursor can move only in the RS232C setup zone 6 2 2 ST2883 RS232C interface RS 232 standard also called as asynchronous s...

Страница 34: ...hat the instrument sends to PC 6 2 2 1 Baud Rate ST2883 provides five baud rates 4800bit 9600bit 19200bit 38400bit 115200bit They are soft keys used to choose the required baud rate Lighten this key t...

Страница 35: ...6 2 3 USB interface Move the cursor to this zone following soft keys can be used USBCDC Set USBCDC interface as the USB interface USBTMC Set USBTMC interface as the USB interface Lighten this key to e...

Страница 36: ...ST2883 USB Vcom Port COM3 in the device manager as shown in figure 6 5 Figure 6 5 USBCDC has been installed Now USB VCom port acts as a serial port When PC has no serial port the communication softwa...

Страница 37: ...h a USB cable Install drive The installing steps of USBTMC are the same as that of USBCDC see 6 2 3 1 for reference When the installation of drive is finished user can see USB Test and Measurement Dev...

Страница 38: ...to a router peer to peer network cable should be used Parameter settings Select LAN interface in the interface page to enter the LAN setup page Now you can set the following parameters IP address SUB...

Страница 39: ...upgraded version Steps of the access to ST2883 trough a browser assume that the instrument IP is 192 168 1 140 1 Start up Internet Explorer 2 Input http 192 168 1 140 in the address zone and then pres...

Страница 40: ...etails 6 3 About The About page shows some relevant information of the instrument such as Model Number Serial number Firmware Version System Version There are two soft keys available Reset Factory Fig...

Страница 41: ...e three function pages displayed on the instrument DISP STEUP and SYSTEM 1 DISP Press this key to enter the measurement display page 2 SETUP Press this key to enter the parameter setup page Continuous...

Страница 42: ...le effect on the turn to turn short test and the layer to layer short test of coil but the amplitude of the applied impulse voltage has a great impact on the insulation test of coil ST2883 solves the...

Страница 43: ...rea size comparison is mainly used to compare the energy consumption Differential area comparison is sensitive to energy consumption and inductance change Corona comparison method is the best one for...

Страница 44: ...w limit is larger than the high limit take the product that has the largest unit difference to make electrical test thus judging whether it is a poor product Another way is to average samples see 7 4...

Страница 45: ...ocess of BDV test the secondary display zone displays not only the extraction value of the corona but also the chart record of differential area after each test The chart can help user observe the cha...

Страница 46: ...Comp aRea On Space _ indicates a space must not be placed before and or after a colon For example COMP _ _ AREA ON COMP AREA ON Space is used to partition off command and parameter Commands locate bef...

Страница 47: ...ic to obtain the short form For example Mass MEMory abbreviates to MMEM long form is MMEMory Impulse VOLTage abbreviates to IVOLT long form is IVOLTage NOTE At the process of commands the instrument d...

Страница 48: ...cter decimal 10 is the end of the input output string END EOI terminator signal of IEEE 488 bus Angular brackets enclose words or characters that are used to symbolize a program code parameter or a GP...

Страница 49: ...DISP indicates that the current displayed page is the measurement display page MEAS SETUP indicates that the current displayed page is the measurement setup page INT FILE indicates that the current d...

Страница 50: ...is OFF For example WrtCmd DISP GRID ON the grid display mode is ON Query syntax DISPlay GRID Return format Off NL END On Where Off means that the current grid display mode is OFF On means that the cur...

Страница 51: ...e 8 4 Measure Function subsystem command tree Command syntax MFUNCtion Function name They are IW BTEST Where IW The measure function is in the turn to turn insulation test mode BTEST The measure funct...

Страница 52: ...ANGe start pot end pot DIFFerence value PHASediff STATe ON 1 OFF 0 POSition value DIFFerence value Figure 8 5 COMParator subsystem command tree The STATe command sets the comparator function to ON or...

Страница 53: ...omparison range from 0 to 6000 NOTE The end point value should be larger than that of the start point otherwise an error message will be displayed on the system message line Query syntax COMP AREA RAN...

Страница 54: ...otherwise an error message will be displayed on the system message line Query syntax COMP DIFF RANG Return format start pot end pot NL END start pot end pot are NR1 format The DIFFzone DIFFerence comm...

Страница 55: ...difference limit value of the Corona comparator The COROna DIFFerence query returns the current difference limit value of the Corona comparator Command syntax COMParator COROna DIFFerence value Where...

Страница 56: ...format NR2 NL END 8 4 4 Impulse VOLTage subsystem commands The Impulse VOLTage subsystem commands set the impulse voltage average times impulse voltage auto adjust and delay etc Figure 8 6 shows the I...

Страница 57: ...Break VOLTage returns no unit and the default voltage unit is V The TIMPulse command sets the average times for testing The TIMPulse query returns the current average times Command syntax IVOLTage TI...

Страница 58: ...he INT test mode The DTIME query returns the current delay time Command syntax IVOLTage DTIME value Where value can be NR1 NR2 or NR3 format followed by s or ms The set delay time ranges from 0 to 99...

Страница 59: ...e standard waveform is tested in the mode of SEQ CYPLE or SINGLE SAMPLE this command will be ignored 2 When the standard waveform is tested in the mode of SINGLE CYCLE if the test has not put an end t...

Страница 60: ...d sets the sample mode of the standard waveform The SMODE query returns the current sample mode Command syntax SCYCLe SWAVE SMODE OCYCLe OSAMPle Where SCYCLe Set the standard waveform sample mode to s...

Страница 61: ...returns standard waveform data when each sampling test is completed In ONE CYCLE mode ST2883 returns the last standard waveform and returns the standard waveform when sample rate is changed The CHOos...

Страница 62: ...1 Where RIGHt Move the waveform to the right 1 Move the waveform to the right LEFT Move the waveform to the left 1 Move the waveform to the left The EXTend command is used to extend the waveform Comm...

Страница 63: ...e The STATe command sets the statistic function to ON or OFF The STATe query returns the current state of the statistic function Command syntax ON STATistic STATe OFF 1 0 Where 1 decimal 49 When the f...

Страница 64: ...is in the testing state The trigger mode must be set to BUS mode or this command will be ignored This command is only used to trigger the test of DUT Refer to Standard WAVE subsystem commands for the...

Страница 65: ...the returned data format The Comparison RESult query returns the latest comparison result Query syntax FETCh CRESult Return format There are three cases as follows 1 If the comparator function or four...

Страница 66: ...total test times for Diff Zone comparison and times of PASS total test times for Corona comparison and times of PASS total times for Phase Diff comparison and times of PASS PASS rate can be automatic...

Страница 67: ...ASure FREQuency Return format start end NL END Both start and end are NR1 format The TIME command sets the time range The TIME query returns the current time range Command syntax MEASure TIME star end...

Страница 68: ...ll display the saved page The SAVE STATe or STORe STATe command is used to save the current setting data to a file Command syntax MMEMory STORe STATe record number filename Where record number is the...

Страница 69: ...ommand Command syntax TRG For example WrtCmd TRG NOTE This command is only available on the MEAS DISP pages This command will also be ignored when ST2883 is in the testing state This command is only u...

Страница 70: ...OLT 60000 the impulse voltage is out of its range Error parameter Unrecognizable parameter is used For example TRIG SOUR INTER INTER is not the correct short form and should not used Error unit suffix...

Страница 71: ...ata however is not valid until BUSY is asserted to low PIN BUSY ST2883 series is in the test state When calculation comparison and display are all completed this signal is asserted to low PIN PASS Pas...

Страница 72: ...DC output pins 2 through 5 is the collector output of the built in pull up resistor and isolated by an opto coupler The output voltage of each line is set by a pull up resistor on the handler interfa...

Страница 73: ...xternal voltage source used for output signal Figure 9 2 Simplified diagram of the input signal In figure 9 2 the default jumper setting is to use external voltage source Actually the input signals an...

Страница 74: ...ure 9 3 Figure 9 3 Jumper position on the Handler interface board As above figure shown when shipped from the factory both jumpers are set at the upper position If you want to apply the internal power...

Страница 75: ...ts in material and workmanship for a period of one year from the date of shipment You should supply us with the warranty card before you enjoy the free maintenance service This warranty does not apply...

Отзывы: