1.800.338.7337 / www.soundoffsignal.com
6
7X3 POLYCARB_WARNING 1121
FUNCTION TABLE 1
WIRE
LIGHT
RED
ORANGE WHITE
SINGLE
+9-32V
FLASH
+9-32V
CRUISE
+9-32V
+9-32V
FLASH
+9-32V
NO OP
+9-32V
+9-32V LOW PWR FLASH
+9-32V
+9-32V
CRUISE
+9-32V
+9-32V
+9-32V LOW PWR FLASH
FUNCTION TABLE 2
WIRE
LIGHT
RED
ORANGE WHITE
SINGLE
+9-32V
FLASH
+9-32V
STEADY COLOR 1
+9-32V
+9-32V
STEADY COLOR 1
+9-32V
NO OP
+9-32V
+9-32V
CRUISE
+9-32V
+9-32V
STEADY COLOR 1
+9-32V
+9-32V
+9-32V
STEADY COLOR 1
AFTER SELECTION
The light will "wink" to indicate which of the new tables is selected.
Custom table will "wink" 7 times.
FUNCTION TABLE 3
WIRE
LIGHT
RED
ORANGE WHITE
SINGLE
+9-32V
FLASH
+9-32V
LOW PWR FLASH
+9-32V
+9-32V
LOW PWR FLASH
+9-32V
NO OP
+9-32V
+9-32V
LOW PWR FLASH
+9-32V
+9-32V
LOW PWR FLASH
+9-32V
+9-32V
+9-32V
LOW PWR FLASH
FUNCTION TABLES
The functional operation of the LED module can be changed while applying the +V to the Red wire with the Black wire connected to ground. When the light is flashing, momentarily connect the White wire to ground
for >4S and <5S (light will go steady high, steady low, off, steady high, steady low) then release. The function table will now advance to the next table (table 1 to table 2 or table 2 to table 3. In the case that the
custom table is programmed, the order is 1 to 2, 2 to 3 and 7 to 1.) Repeat above process until required function table is active.
WIRING AND TABLE INFORMATION (CONT.)
EXAMPLE: If the light is using Function Table 2 with the Orange wire to power, which steady burns color 2, and you then apply the White wire to ground,
to change the Function Table to number 3, this would cause the light to start flashing dual low power.