# Setup
Name
Description
Options
Factory
Default
52.
Output 1: Analog Gain
Sets the attenuation level of each
analog output bus.
Selectable from -40 to 0 dB in 1 dB incre-
ments
-4 dB
53.
Output 2: Analog Gain
54.
Output 3: Analog Gain
55.
Output 4: Analog Gain
56.
Output 5: Analog Gain
57.
Output 6: Analog Gain
58.
Digital Input: AES42 Power
Pr10 V of Digital Phantom
Power to each digital input. Never
apply digital phantom to unbalanced
digital inputs, as this can result in
damage to the hardware.
• Disabled
• Enabled
Disabled
59.
Digital Output: Mode
Selects whether or not the consumer
SPDIF bit is applied or not in the
AES3id output.
• Consumer
• Professional
Professional
60.
Play: AutoPlay Mode
Allows the user to play file(s) con-
secutively from a select directory, one
time through or continuously.
Great for playing an MP3 collection
during down time!
• Disabled
• Play all
• Repeat one
• Repeat all
Play all
61.
Time/Date: 12/24 Hr
Selects between 12- and 24-hour
formats.
• 12 hr
• 24 hr
12 hr
62.
Time/Date: Date Format
Selects the date syntax of the
recorder.
• mm/dd/yy
• dd/mm/yy
mm/dd/yy
63.
Time/Date: Set
Sets the internal date and time of
the 788T.
Resetting the time re-jams the inter-
nal time code generator to the set
time. Setting the internal clock during
a production day will require time
code devices to be re-jammed.
<time, date>
Clock is not set until <done> is selected
64.
LCD: Contrast
Adjusts the contrast level of the LCD
display.
0–100%
65.
LCD: Backlight Mode
Enables or disables the LCD
backlight color from indicating that
the 788T is in Record, Playback, or
Standby.
• White/Green/Red
• Red on Record Only
• Green on Play Only
• White Only
White/Green/Red
66.
LCD: Scrolling Direction
Defines the direction in which the Ro-
tary Switch will navigate throughout
the 788T.
• Normal
• Reverse
Normal
67.
Meter: Scale
Selects meter scale in dBFS. Stan-
dard and Zoom options are factory
settings. Custom meter scales can be
set by adding a new entry and edit-
ing the meter scale. The * indicates
Favorite mode. Press and hold the
Backlight key to toggle between the
selected meter scale and the favorite.
Lists are saved to a METERSCALED
folder within the INHDD SOUNDDEV
folder.
• Standard
• Zoom
• <Add New Entry>
• <Load List From INHDD>
• <Save List From INHDD>
• <Load Default List>
• <Set Favorite>
Standard
Zoom is Favorite
68.
Meter: Ballistics
Selects among three different meter
ballistics settings
• VU only
• Peak only
• Peak + VU
Peak + VU
788T/788T-SSD User Guide and Technical Information
154
v. 3.01
Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.