background image

 

User Manual 

CP8

 

Rev1.0   

 

 

 

Connection type: RS-485

 

The CP8 communication to the DPA880T is by RS485. +1 and -2 are only required pins from the 

RJ45 

Power Supply 

Power supply DC +12V is required to power the CP8 (not supplied with the panel) 

 

To programme CP8: 

 

CP8 you can set user defined as either Master Mode or Zone ModeUser. The following instruction 

explains the process 

 

 

 

"Set" button is used to access the various menus and to confirm 

 

"Esc" button is used to exit from the menus   

 

"Encoder" The large rotary encoder is used to enter and exit the standby mode if the key is 

pressed for around 5-6 sec. Or with the single press allows setting the steps for changing 

the values of Gain and Volume (Gain =-127dB to + 12dB; Volume =-127dB to + 18dB) 

 

The Encoder is also used to move between the various menus and changing the values of 

the parameters. 

 

LCD display 2 x 20 alphanumeric 

 

Power ON Led: when lit indicates that the system is powered 

 

Eth Led: when lit indicates that the CP8 is communicating with the DPA880T 

 
 
 
 
 

Содержание CP8

Страница 1: ... the various menus and to confirm Esc button is used to exit from the menus Encoder The large rotary encoder is used to enter and exit the standby mode if the key is pressed for around 5 6 sec Or with the single press allows setting the steps for changing the values of Gain and Volume Gain 127dB to 12dB Volume 127dB to 18dB The Encoder is also used to move between the various menus and changing th...

Страница 2: ...MODE The SYSTEM SETUP mode is used by the installer to configure the CP8 Configure Mode Using this menu you can configure the CP8 as Master Control or Zone Control Configure ID Through this menu it is possible to configure the ID for the communication with the DPA880T device the ID setting of the CP8 must be the same the setting in the DPA880T Configure standby with this menu you can configure the...

Страница 3: ... to match the device Press the SET button to confirm and exit press ESC to cancel and exit After selecting the menu using the Encoder you can configure the standby mode Pressed the SET button then via Encoder select between Off or On SYSTEM SETUP Configure Mode Configure Mode Mode Master Configure Mode Mode Zone SYSTEM SETUP Configure Mode Configure ID ID 01 SYSTEM SETUP Configure ID SYSTEM SETUP ...

Страница 4: ...nd input Mute Select Output Via this menu you can configure the volume and Mute Load Program Through this menu you can load anyone of the 6 presets Info Via this menu the model version and ID set is displayed Lock Through this menu it is possible to Lock the CP8 1 SELECT INPUT SYSTEM SETUP Configure Stand by SYSTEM SETUP Configure Zone Configure Zone Zone 01 SYSTEM SETUP Configure Zone Configure Z...

Страница 5: ...PA880T or the ID is not correct then the display will show the following message and after 2 sec The Eth led will turn off and the system will go back to the menu If communication is successful then the display will show the current status of the Mute through Encoder it is possible to change the status of the Mute from ON to OFF or vice versa in real time and the parameter will be updated on DPA88...

Страница 6: ...lay will show the current status of Gain through Encoder it is possible to change the Gain value Gain varies between 127 0 dB to 12dB and in real time the parameter will be updated on DPA880T Using Encoder it is possible to change the gain variation in steps of 0 1 dB or 1dB Press the Esc key to return to the start screen 2 SELECT OUTPUT After pressing the SET button via Encoder you can select bet...

Страница 7: ...f communication is successful then the display will show the current status of the Mute through Encoder is possible to change the status of the Mute from ON or OFF or vice versa in real time and the parameter will be updated on DPA880T Press the Esc key to return to the start screen If you selected Volume and press SET on the display you will see the following screen the Eth led will be turned on ...

Страница 8: ... which preset is loaded and read the names of the program If the preset currently uploaded on DPA880T is an extra presets preset from 7 to 10 activated via inputs S1 S4 available on the back panel the display will then show the message and after 2 sec The Eth led turns off and returns to the previous screen This is because the extra presets are associated with special events and these have priorit...

Страница 9: ...e ESC key to exit the submenu Press the SET button to load the selected preset and exit from submenu During the upload phase the led will be lit and Eth on the display will show the following message When loading if the Eth led turns off the system will go back to the main menu 4 INFO After pressing the SET button CP8 CTRL PANEL Info Model CP8 ID 01 Version 1 0 0 CP8 CTRL PANEL Load Program Load P...

Страница 10: ...d the panel this is done by simultaneously pressing the keys ESC and SET for around 5 6 sec After that the system will be unlocked ZONE MODE Mode the symbol _ can be a number between 1 and 8 CP8 CTRL PANEL Lock CP8 CTRL PANEL Info Lock CP8 Are you sure CP8 CTRL PANEL Lock CP8 CTRL PANEL System Locked CP8 CTRL PANEL Select Input CP8 CTRL ZONE_ Select Routing CP8 CTRL ZONE_ Zone Control CP8 CTRL ZON...

Страница 11: ...Zone If the CP8 is not connected to the DPA880T or the ID is not correct then the display show the following message and after 2 sec The Eth led will turn off and the system will go back to the menu If communication is successful then the display will show the selection and using the Encoder you can select between Input 1 8 After selecting an entry eg Input2 and press the SET button It is possible...

Страница 12: ...ss the Esc key to return to the start screen 2 SELECT ZONE After pressing the SET button via Encoder you can select between Mute or Volume If you select Mute and press SET on the display you will see the following screen the Eth led will turn on because the system sends a message to DPA880T asking for the current state of mute on the Zone selected If the CP8 is not connected to the DPA880T or the ...

Страница 13: ...led will turn on because the system sends a message to DPA880T asking for the current status of the volume for the selected zone If the CP8 is not connected to the DPA880T or the ID is not correct then on the display will appear the following message and after 2 sec The Eth led will turn off and the system will go back to the menu If communication is successful then the display will display the cu...

Страница 14: ...urn to the start screen 3 INFO After pressing the SET button Press the SET button or the ESC key to return to the menu 4 LOCK After pressing the SET button the system asks for confirmation If pressed Esc returns you to the menu If press SET the system goes into Lock mode Zone 2 Volume CP8 CTRL PANEL Info Model CP8 ID 01 Version 1 0 0 CP8 CTRL PANEL Info CP8 CTRL PANEL Lock Lock CP8 Are you sure CP...

Страница 15: ...n this case the only way possible to unlock the system is by simultaneously pressing the keys ESC and SET for around 5 6 sec CP8 Connection Details RS485 RS485 Red 12V Black RS485 RS485 RS485 RS485 RS485 ...

Страница 16: ... 2 The ID on CP8 must be set the same as the DPA880T ...

Отзывы: