XAV-AX210
5
Sony CONFIDENTIAL
For Authorized Servicer
DESTINATION CHECKING METHOD
When replacing the MAIN board, perform works according to the
following procedure.
If the correct destination code is not displayed, it is necessary to set
the destination.
Note 1:
Remote commander is necessary for destination checking opera-
tion.
Procedure:
1. After replacing the MAIN board, assemble the main unit to the
normal condition, and connect the regulated DC power supply.
+
–
Regulated DC
power supply
2. Press the [OFF] button on the remote commander to the state
of source off, enter the test mode by pressing the buttons on the
remote commander in order of the [4]
t
[5]
t
[0] (press only
the [0] button for two seconds).
(Displayed screen in the above
fi
gure are example)
3. Con
fi
rm the alphanumeric character of 2 digits of “DEST” on
the screen display is a value of “01”.
Note 2:
If “01” is not displayed or another alphanumeric character is dis-
played, perform “DESTINATION SETTING METHOD” on the
right.
DEST :
01
MCU :
SONY-ST28-1800615 1.00.01.00
SOC :
1.00.01.00
APP :
180615-1f65bac
SYS :
180615-7004c7f
SDK :
21.5.0.3.0.0.0.0
GUI :
3.15.0
BT Address : fc:4b:bc:f8:69:64
Serial :
3166000701900029
DVD Region: 1
Servo: SAHSWD-ABA-097C
DEST: 01
(Displayed characters/values in the above
fi
gure are example)
4. The resetting operation is executed by pressing the reset button
after the con
fi
rming ends, then the unit reboots and returns to the
normal condition.
DEST :
01
MCU :
SONY-ST28-1800615 1.00.01.00
SOC :
1.00.01.00
APP :
180615-1f65bac
SYS :
180615-7004c7f
SDK :
21.5.0.3.0.0.0.0
GUI :
3.15.0
BT Address : fc:4b:bc:f8:69:64
Serial :
3166000701900029
DVD Region: 1
Servo: SAHSWD-ABA-097C
[Reset] button
(Displayed characters/values in the above
fi
gure are example)
5. This completes the destination check work.
DESTINATION SETTING METHOD
After replacing the MAIN board, perform the following procedure,
only when con
fi
rm the destination code and the correct destination
code is not displayed.
Note 1:
This work is unnecessary if “DESTINATION CHECKING METH-
OD” on the left is performed and the correct destination code is
displayed.
Note 2:
Remote commander is necessary for destination setting operation.
Setting procedure:
1. Refer to “3. DISASSEMBLY” on page 15, disassemble until to
the state that side A of MAIN board can be seen.
Note 3:
The following is an image view. Be sure to refer to “3. DISASSEM-
BLY” on page 15 for detail.
top cover
mechanism deck
2. Short-circuit the shortland (SL001) on the MAIN board by sol-
dering.
rear
side
front
side
– MAIN board (Side A) –
– Continued on next page –
SYS SET
2018/09/12 22:50:21 (GMT+09:00)