2-48
UWP Series
5. Overall Characteristics Check
Perform the overall characteristics check according to the
following procedure.
Procedure
(1) Output Level Check
(2) S/N Check
(3) Frequency Characteristic Check
(4) Distortion Ration Check
(5) RF Squelch Level/RF Indicator Check
(6) RF Level Indicator Check
(7) AF Level Indicator/AF Indicator Check
(8) Tone Squelch Check
Equipment and Tools
.
Signal generator
.
Function generator
.
Audio analyzer
.
Mic amp
.
Oscilloscope
.
DC current meter
.
MM-SMA conversion connector : (Part No. J-6402-490-A)
.
RF adjusting cable : (Part No. J-6402-390-A)
.
AF output cable : (Part No. 1-792-249-11)
Connection
Oscilloscope
Signal
generator
Function
generator
MIC
amplifier
Make it as short
as possible.
(Connect directly
if possible)
Make it as short
as possible.
RF
adjusting
cable
RF adjusting
cable
CN101 or CN201
MM-SMA
conversion
connector
MM-SMA
conversion
connector
Connect GND of all
equipment within the
shortest possible length.
Audio
analyzer
AF output
cable
Ant-a
(CN201)
Ant-b
(CN101)
Monitor
RF-130 board
(A side)
Output
RV181 RV281
(1) Output Level Check
1.
Set the URX-P2 as follows :
Channel setting :
U30 model
;Group 03, 3201 channel (578.125 MHz)
U42 model
;Group 03, 4401 channel (650.125 MHz)
CE62 model ;Group 04, 6332 channel (810.000 MHz)
CE67 model ;Group 04, 6832 channel (850.000 MHz)
KR model
;Group 12, 6001 channel (746.125 MHz)
RF Squelch : OFF (For setting, refer to “Setting the
Squelch OFF mode” on page 2-42)
Monitor level: MON.01 (minimum value)
2.
Connect an audio analyzer to the OUTPUT connector
via the MIC amplifier (with the 0 dB gain setting).
3.
Connect the signal generator to the CN201/RF-130
board with the MM-SMA conversion connector and
the RF adjusting cable.
4.
Set the signal generator as follows :
Signal generator setting
U30 model
; 578.125 MHz
U42 model
; 650.125 MHz
CE62 model
; 810.000 MHz
CE67 model
; 850.000 MHz
KR model
; 746.125 MHz
RF OUTPUT (Output level) : 60 dB
u
V
EMF
(=
_
53 dBm)
MODULATION (Modulation frequency) : 100 Hz
DEVIATION (Frequency deviation)
:
±
10 kHz
5.
Check that the OUTPUT connector output level is
_
46
dBm
±
0.5 dB (at 600
Z
loaded).
6.
Connect the signal generator to the CN101/RF-130
board with the MM-SMA conversion connector and the
RF adjusting cable.
7.
Perform the procedures 4 to 5 above.
n
The output level difference between the ANTENNA A
IN side and the ANTENNA B IN side should be
within 0.5 dB.
Содержание UWP-V1
Страница 4: ......
Страница 20: ......
Страница 94: ...3 6 UWP Series URX M2 3 2 3 URX M2 4 9 11 6 10 10 2 3 1 8 8 9 5 7 ...
Страница 130: ......
Страница 131: ...4 1 UWP Series 4 1 Section 4 Block Diagrams and Circuit Descriptions ...
Страница 142: ......
Страница 147: ...5 5 UWP Series 5 5 MB 1094 A SIDE SUFFIX 11 MB 1094 B SIDE SUFFIX 11 MB 1094 MB 1094 5 5 UTX P1 ...
Страница 148: ......
Страница 163: ......
Страница 164: ...Printed in Japan Sony Corporation 2008 6 16 2008 UWP V1 V2 V6 X7 X8 U CE KR E 9 976 937 01 ...