2-42
UWP Series
2.
Connect the DC power supply (DC +3 V
±
0.1 V) and
the DC ammeter as shown in the following figure.
Check
DC current meter indication level
(under no-RF signal input and SQUELCH OFF mode) :
200 mA or less
Battery terminal
RF-130 board
CN-3092 board
CPU-421 board
(
+
)
(
_
)
+
_
+
_
Black
Battery terminal
Red
DC power supply
DC ammeter
output voltage
: DC
+
3.0
±
0.1V
1. Current Consumption Check
Equipment and Tools
.
DC power supply
DC output voltage :
+
3.0Vdc
±
0.1 V
.
DC ammeter
.
Digital volt meter (or Digital multimeter)
Switch and Control Setting
Set the URX-P2 as follows :
Channel setting :
U30 model ; Group 03, 3201 channel (578.125 MHz)
U42 model ; Group 03, 4401 channel (650.125 MHz)
CE62 model ; Group 04, 6332 channel (810.000 MHz)
CE67 model ; Group 04, 6832 channel (850.000 MHz)
KR model
; Group 12, 6001 channel (746.125 MHz)
RF Squelch : OFF (For setting, refer to “Setting the
Squelch OFF mode” on page 2-42)
Monitor level : MON.01 (minimum value)
Preparation
1.
Check the current consumption with the RF-130 board,
CN-3092 board, and battery terminal connected to the
CPU-421 board after removing the two antennas,
CPU-421 board, RF-130 board, and CN-3092 board
from the URX-P2 unit.
(For the removal method, refer to section 1-1-1.)
Содержание UWP-V1
Страница 4: ......
Страница 20: ......
Страница 94: ...3 6 UWP Series URX M2 3 2 3 URX M2 4 9 11 6 10 10 2 3 1 8 8 9 5 7 ...
Страница 130: ......
Страница 131: ...4 1 UWP Series 4 1 Section 4 Block Diagrams and Circuit Descriptions ...
Страница 142: ......
Страница 147: ...5 5 UWP Series 5 5 MB 1094 A SIDE SUFFIX 11 MB 1094 B SIDE SUFFIX 11 MB 1094 MB 1094 5 5 UTX P1 ...
Страница 148: ......
Страница 163: ......
Страница 164: ...Printed in Japan Sony Corporation 2008 6 16 2008 UWP V1 V2 V6 X7 X8 U CE KR E 9 976 937 01 ...