Operating Instructions
AWG2021 Service Manual
2-17
The clock period is the time between the data points for the waveform
created. Therefore, the product of the clock period and the number of
waveform points is the waveform or sequence period. For example, if
the clock frequency is 1 MHz (period of 1
m
s) and there are 100
waveform points, the waveform period is displayed as 100
m
s.
With Option 02 (the CH2 output option) installed, the CH2 clock is the
CH1 clock frequency divided by any value entered for Divider.
H
Operation. This item performs an arithmetic operation between the CH1
waveform and another waveform, and outputs the result at the CH1
output connector. The operations are addition (Add) and multiplication
(AM, External AM).
If the AWG2021 has only one channel, the items available are External
AM and Normal. With Option 02 (the CH2 output option) installed, the
operations available are Add, AM, External AM, and Normal.
H
Filter. This item selects a filter that restricts the frequency band for the
output channel. Choose a 50, 20, 5, or 1 MHz filter, or you can select
Through (no filter).
H
Ampl. This selection sets the voltage value for the 12-bit, full-scale,
output amplitude on the vertical scale. The amplitude can be set in steps
of 1 mV within the range from 0.05 V to 5 V.
H
Offset. This item sets the offset level of the output waveform. The offset
can be set in steps of 5 mV within the range
±
2.5 V.
The MODE menu initiates the waveform output with the output conditions set
using the SETUP menu.
1. Push the MODE button in the MENU column. The MODE menu in
Figure 2–5 appears.
2. Select the operation mode from the bottom menu. The operation modes are
Cont, Triggered, Gated, Burst, Waveform Advance, and Autostep.
In all modes except Cont, the trigger or gate signal source can be the external
signal applied to the TRIGGER INPUT connector, or a trigger can be
generated by pushing the front panel TRIGGER MANUAL button. The
individual modes are described below:.
H
Cont Mode. When you push the Cont button, the AWG2021 immediately
outputs the specified waveform or sequence waveform, continuously.
H
Triggered Mode. In triggered mode, the AWG2021 outputs the specified
waveform or sequence waveform once, when a trigger occurs.
Operation Mode Settings
Содержание Tektronix AWG2021
Страница 4: ......
Страница 16: ...Service Safety Summary xii AWG2021 Service Manual ...
Страница 21: ...Specifications ...
Страница 22: ......
Страница 39: ...Operating Information ...
Страница 40: ......
Страница 60: ...Operating Instructions 2 20 AWG2021 Service Manual ...
Страница 61: ...Theory of Operation ...
Страница 62: ......
Страница 66: ...Theory of Operation 3 4 AWG2021 Service Manual ...
Страница 67: ...Performance Verification ...
Страница 68: ......
Страница 123: ...Adjustment Procedures ...
Страница 124: ......
Страница 135: ...Maintenance ...
Страница 136: ......
Страница 144: ...Maintenance 6 8 AWG2021 Service Manual ...
Страница 188: ...Removal and Installation Procedures 6 52 AWG2021 Service Manual ...
Страница 196: ...Troubleshooting 6 60 AWG2021 Service Manual TP100 5V TP101 GND Figure 6 34 Key Board ...
Страница 201: ...Options ...
Страница 202: ......
Страница 222: ...Options and Accessories 7 20 AWG2021 Service Manual ...
Страница 223: ...Replaceable Electrical Parts ...
Страница 224: ......
Страница 226: ...Replaceable Electrical Parts 8 2 AWG2021 Service Manual ...
Страница 227: ...Diagrams ...
Страница 228: ......
Страница 230: ...Diagrams 9 2 AWG2021 Service Manual ...
Страница 236: ...9 8 AWG2021 Service Manual ...
Страница 237: ...Replaceable Mechanical Parts ...
Страница 238: ......
Страница 253: ...Replaceable Parts AWG2021 Service Manual 10 15 4 5 1 2 3 12 13 11 1 11 10 A23 A31 6 7 8 9 Figure 10 6 Option 02 ...
Страница 255: ...Replaceable Parts AWG2021 Service Manual 10 17 2 5 1 3 4 A9 2 Figure 10 7 Option 03 ...
Страница 257: ...Replaceable Parts AWG2021 Service Manual 10 19 3 1 2 A25 4 Figure 10 8 Option 04 ...
Страница 261: ......
Страница 262: ......