6-3.
Forced Version Update
If the version of program or data cannot be updated from the ROM VERSION page of the DIAGNOSIS menu, the
software or PLD data version can be updated by the “forced version update.”
6-3-1.
Forced Version Update of Software or PLD Data
Equipment Required
USB drive (commercially available)
Tip
For recommended USB drive, refer to “Using a USB Drive” in the operation manual.
Preparation
Copy the software or PLD data version update data file to the USB drive using the following procedure.
Note
For how to obtain the version update data file, contact your local Sony Sales Office/Service Center.
1.
Create the following directory in the USB drive.
\MSSONY\PRO\CAMERA\HDC4300
2.
Copy the version update data file to be updated to the directory created.
Note
Do not copy software or PLD data that is not to be updated.
Procedure
1.
Connect the USB drive that contains the version update program.
2.
Turn on the unit while pressing the RET 2 button and the rotary encoder on the front of the unit.
The version of each version update data file copied in the USB drive is updated.
Tip
The version update progress status is displayed on the viewfinder.
3.
Upon completion of the version update, a message “UPDATE SUCCEEDED” appears.
4.
Turn off and on the unit and confirm that the version has been updated on the “ROM VERSION” page of the
DIAGNOSIS menu.
HDC4300
6-5
Содержание super motion hdc4300
Страница 1: ...COLOR CAMERA HDC4300 SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 12: ......
Страница 46: ......
Страница 134: ......
Страница 140: ......
Страница 174: ......
Страница 178: ......
Страница 205: ......
Страница 206: ...HDC4300 SY HDC4300 CED HDC4300 CN HDC4300 J J E 9 878 636 01 Sony Corporation Printed in Japan 2015 4 08 2015 ...