• Lens iris: F4 to F5.6
• A = 600 ±20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
A
Procedure
1.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Detail] → [1/3] → [Level Dep]
2.
Set adjustment item [Level Dep] to -99 by adjustment nob of MSU.
3.
Adjust the level dependent.
• Adjustment item : [Level Dep]
(1) Turn the adjustment knob of MSU to plus direction slowly.
(2) Stop the adjustment knob of MSU at the where the edge of B portion on the waveform just decreases. Or
adjust for the desired level.
B
4.
Store the reference file.
Refer to the
.
5.
After completing this adjustment, perform
.
5-4-5.
Detail Clip Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Object: Grayscale chart
Preparation
• Setting for
DETAIL OFF button → ON (dark)
KNEE OFF button → OFF (lit)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: F4 to F5.6
HDC4300
5-20
Содержание super motion hdc4300
Страница 1: ...COLOR CAMERA HDC4300 SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 12: ......
Страница 46: ......
Страница 134: ......
Страница 140: ......
Страница 174: ......
Страница 178: ......
Страница 205: ......
Страница 206: ...HDC4300 SY HDC4300 CED HDC4300 CN HDC4300 J J E 9 878 636 01 Sony Corporation Printed in Japan 2015 4 08 2015 ...