2.
Adjust the levels B to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
• Adjustment item : [R], [G], [B], [Master]
B
3.
Store the reference file.
(Refer to the
5-4-9.
Gamma Correction Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Object: Grayscale chart
Preparation
• Setting for MSU
KNEE OFF button → OFF (lit)
GAMMA OFF button → ON (dark)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: A = 700 ±20 mV
A
Procedure
1.
Operate the control panel of MSU, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
After the adjustment is completed, the message “AWB : OK” is displayed.
2.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Gamma]
HDC4300
5-24
Содержание super motion hdc4300
Страница 1: ...COLOR CAMERA HDC4300 SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 12: ......
Страница 46: ......
Страница 134: ......
Страница 140: ......
Страница 174: ......
Страница 178: ......
Страница 205: ......
Страница 206: ...HDC4300 SY HDC4300 CED HDC4300 CN HDC4300 J J E 9 878 636 01 Sony Corporation Printed in Japan 2015 4 08 2015 ...