3.
Adjust the levels B to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
• Adjustment item : [R], [G], [B], [Master]
B
4.
Store the reference file.
(Refer to the
5-4-10. Knee Point/Knee Slope Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Preparation
• Setting for MSU
MASTER GAIN → 6
TEST 1 button → ON (lit)
KNEE OFF button → ON (dark)
Procedure
1.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Knee] → [Knee Slope]
(3) Set adjustment item[Master] to -99.
2.
Operate the control panel of MSU, and set as follows.
Touch panel operation: (Page 1) → [Knee] → [Knee Point]
3.
Adjust the levels A to desired level for R, G and B respectively.
。
To adjust all levels for R, G and B simultaneously, adjust them using Master.
• Adjustment item : [R], [G], [B], [Master]
• Reference value : A = 686 mV
A
4.
Operate the control panel of MSU, and set as follows.
Touch panel operation: (Page 1) → [Knee] → [Knee Slope]
5.
Adjust the levels B to desired level for R, G and B respectively.
• Adjustment item : [R], [G], [B], [Master]
• Reference value : B = 735 mV
B
HDC4300
5-25
Содержание super motion hdc4300
Страница 1: ...COLOR CAMERA HDC4300 SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 12: ......
Страница 46: ......
Страница 134: ......
Страница 140: ......
Страница 174: ......
Страница 178: ......
Страница 205: ......
Страница 206: ...HDC4300 SY HDC4300 CED HDC4300 CN HDC4300 J J E 9 878 636 01 Sony Corporation Printed in Japan 2015 4 08 2015 ...