3.
Adjust the H/V Ratio adjustment, a ratio between H and V detail amounts (white) to be added shall be equal.
• Adjustment item : [H/V Ration] (Reference value: 20 to 40)
H
V
4.
Change the settings to the recorded customer’s settings.
5.
Store the reference file.
(Refer to the
5-4-2.
Detail Level Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Object: Grayscale chart
Preparation
• Setting for MSU
DETAIL OFF button → ON (dark)
KNEE OFF button → OFF (lit)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: F4 to F5.6
• A = 600 ±20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
A
Procedure
1.
Operate the menu of MSU.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Detail] → [1/3]
2.
Adjust the detail level to be added to each step of the grayscale to the desired level.
• Adjustment item : [Level]
3.
Store the reference file.
(Refer to the
HDC4300
5-18