3
STR-DE597
Video section
Inputs/Outputs
Video:
1 Vp-p, 75 ohms
COMPONENT VIDEO:
(Except for models of area code AEP, UK)
Y: 1 Vp-p, 75 ohms
P
B
/C
B
/B-Y: 0.7 Vp-p,
75 ohms
P
R
/C
R
/R-Y: 0.7 Vp-p,
75 ohms
80 MHz HD Pass Through
General
Power requirements
Area code
Power requirements
US, CND
120 V AC, 60 Hz
AEP, UK
230 V AC, 50/60 Hz
AUS
240 V AC, 50 Hz
SP, MY, AR, KR
220 – 230 V AC, 50/60 Hz
E2
120/220/240 V AC, 50/60 Hz
Power consumption
Area code
Power consumption
US, AEP, UK, E2, AUS,
220 W
SP, MY, AR, KR
CND
300 VA
Power consumption (during standby mode)
0.3 W
Dimensions (w/h/d) (Approx.)
430
×
157.5
×
312 mm
(16
7/8
×
6
2/8
×
12
2/8
inches) including
projecting parts and
controls
Mass (Approx.)
8.0 kg (17 lb 11 oz)
Supplied accessories
FM wire antenna (1)
AM loop antenna (1)
Remote commander RM-U306B (1)
R6 (size-AA) batteries (2)
Design and specifications are subject to change
without notice.
• Abbreviation
CND : Canadian model
E2
: AC 120 V area in E model
AUS : Australian model
SP
: Singapore model
MY : Malaysia model
AR : Argentina model
KR : Korea model
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK
0
OR DOTTED LINE
WITH MARK
0
ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERA TION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE
0
SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES
SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT.
NE REMPLACER CES COMPOSANTS QUE P AR DES PIÈCES
SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL
OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
1.5 k
Ω
0.15
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY CHECK-OUT (US MODEL)
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to an y exposed metal part ha ving a
return to chassis, must not e xceed 0.5 mA (500 micr oampers.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a r esistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indica-
tion is 0.75 V, so analog meter s must have an accurate lo w-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passi ve VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are suit-
able. (See Fig. A)
Fig. A. Using an AC voltmeter to check AC leakage.
Содержание ST-RDE597
Страница 5: ...5 STR DE597 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 6: ...6 STR DE597 ...
Страница 59: ...59 STR DE597 MEMO ...