2-7
SSC-M183/M183CE/M188CE/M383/M383CE/M388CE
SSC-DC193/DC193P/DC198P/DC393/DC393P/DC398P
2-4. Correction of Residual Point Noise
1.
Connect one end of the RS-232C cable to the COM
(RS-232C) port of the PC and other end to the
connector (CN1) on the adjusting tool board.
2.
Connect the adjusting tool board (CN205/PC-2001
board) to the camera and turn on the power.
3.
Start the PC.
4.
After starting the PC, start the adjustment software
“BoxCam.exe”.
5.
In “SelectCOM”, select the port to which the RS-232C
cable is connected.
6.
Click the “Defect Compensation Mode” button. The
current data is read from the camera.
7.
After completion of the reading, the following
message is displayed.
8.
With R and YL adjusted to be within each smaller
area, check that the luminance points of MG, B, G, and
CY are also partly within the range of each color
reproduction. When there are spots out of the range,
make adjustment by performing steps 4 to 7 so that all
the luminance points are within each range.
2-3-6. Writing
1.
After completing the adjustment, press the TAB key to
make the END button active state. (Refer to Section 2-
3-3, Step 1)
2.
After the END key becomes active state, press the
Enter key.
The writing of adjustment data is executed. The
writing will be completed in about 5 seconds.
3.
After the message for the completion of writing is
displayed, turn off the power of the unit. Press the OK
button of the message to clear the message.
4.
Disconnect the camera from the harness of the
adjusting tool board, then turn on the power of camera
to check that the writing of adjustment data has been
correctly completed.