The SAITe1300-F (Fibre Channel interface model) and the
host computer cannot communicate with each other
• Verify that the host computer is on.
• Verify the FC status indicator at the rear of the unit. If it is lit orange, there is
a connection error. In this case, reconnect the cable or change it if necessary.
• Verify that an optical fiber cable is correctly connected from the unit to the
host computer, hub, or switch.
• Verify that the optical fiber cable is of the appropriate type. For details, see
“Connecting the Optical Fiber Cable for Fibre Channel (SAITe1300-F only)”
on page 29.
• Verify that the Loop ID is set correctly. For details, see “Setting the Loop ID
(SAITe1300-F only)” on page 23.
Your software does not detect the unit
• Verify that your software supports the S-AIT Tape Drive Unit. For details
about software that can be used on the S-AIT Tape Drive Unit and supported
operating systems, contact your dealer.
• Verify that the software is correctly installed and set up on the host computer.
• If the software requires a device driver, install the appropriate device driver
from the supplied CD-ROM. For details, see “Installing Device Drivers” on
page 26.
Media error detected
Push the eject button. If the cartridge is ejected, reset the unit and try to insert a
new one.
Drive error detected
Push the eject button. If the cartridge is ejected, reset the unit and try to insert a
new one.