background image

30

Chapter 2  Installation

Configuring the S-AIT Tape Drive Unit to the Host

Configure the S-AIT Tape Drive Unit as follows.

1

Turn on the S-AIT Tape Drive Unit.

For details, see “Turning the Unit On or Off” on page 31.

2

To configure the unit for use, refer to the documentation of the host 
computer and software.

Содержание SAITe1300-F

Страница 1: ...SAITe1300 S SAITe1300 F 2003 Sony Corporation 4 679 683 13 2 S AIT Tape Drive Unit Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference ...

Страница 2: ... ziehen welche sich in der Nähe des Gerätes befinden muß und leicht zugänglich sein soll Hinweis Die 3 adrige Geräteanschlußleitung muß Typ H05VV F oder H05VVH2 F sein und nach DIN VDE 0625 geprüft sein Der Stecker und die Gerätesteckdose müssen nach DIN VDE 0620 bzw DIN VDE 0625 geprüft sein Der Leitungsquerschnitt kann 0 5mm2 betragen wenn die Anschlußleitung eine Länge von 2m nicht überschreite...

Страница 3: ...roduktsicherheit EMV und R TTE ist Sony Corporation 6 7 35 Kitashinagawa Shinagawa ku Tokyo 141 0001 Japan der Hersteller dieses Produktes Bevollmächtigter ist Sony Deutschland GmbH Hedelfinger Strasse 61 D 70327 Stuttgart Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in separaten Service oder Garantiedokumenten angegebenen Adressen European Union Restriction of Hazardous S...

Страница 4: ...able recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules If you have any questions about this product please access Sony Support Center written in the warranty card Für Kunden in Deutschland Diese Ausrüstung erfüllt die Europäischen EMC Bestimmungen für die Verwendung in folgender folgende...

Страница 5: ... necessary change the settings as follows 19 Setting the SCSI ID SAITe1300 S only 22 Setting the Loop ID SAITe1300 F only 23 Installing the S AIT Tape Drive Unit 25 Connecting the Power Cable 26 Installing Device Drivers 26 Connecting the SCSI Bus Cable SAITe1300 S only 27 Connecting the Optical Fiber Cable for Fibre Channel SAITe1300 F only 29 Configuring the S AIT Tape Drive Unit to the Host 30 ...

Страница 6: ...aking Care of the Unit 43 Safety 43 Avoiding Damage 44 Troubleshooting 45 Specifications 47 Performance 47 Environmental Specifications 47 Power Specifications Miscellaneous 48 Options 48 Index 49 2003 Sony Corporation All rights reserved Trademarks Sony Advanced Intelligent Tape and Super Advanced Intelligent Tape are trademarks or registered trademarks of Sony Corporation in this country other c...

Страница 7: ...ation and experience in magnetic tape technology The AME tape formulation with diamond like carbon coating offers an extraordinary durability and reliability up to 30 000 media passes and an estimated media archival life of up to 30 years Remote Memory in Cassette R MIC The non volatile R MIC chip built into the data cartridge provides quick media loads and allows fast searches of data The R MIC c...

Страница 8: ...ed search and tape rewind Supports variable and fixed record length 72 MB buffer memory Very compact design that allows you to set two units side by side on a 19 inch rack 2U height Sealed mechanism with the front door and the air filter Very easy to change the air filter Half transparent front panel through which you can verify the cartridge even when the door is closed Sleek and elegant design F...

Страница 9: ...artridges designed specifically for S AIT Cleaning Cartridges To clean the read write heads use the S AIT Cleaning Cartridge SAIT1 CL supplied with the unit For details about cleaning see Head Cleaning on page 41 Supported Software For details about software that can be used with the S AIT Tape Drive Unit and supported operating systems contact your dealer SAIT 1 logo ...

Страница 10: ...ng cartridges Note Even when the front door is closed and a cartridge is ejected by software the cartridge does not come in contact with the door You can therefore keep the door closed except when inserting or removing cartridges to minimize any contamination from airborne particles B DOOR Button Press to open the front door TAPE MOTION DRIVE ERROR TAPE ERROR CLEANING REQUEST OPEN ...

Страница 11: ...tor Flashes yellow when the read write heads need cleaning For details about cleaning see Head Cleaning on page 41 F TAPE ERROR Indicator Flashes or lights orange when media errors occur When media warnings occur the indicator flashes yellow In this case copy data to another cartridge G DRIVE ERROR Indicator Flashes orange or yellow when drive errors occur H TAPE MOTION Indicator Lights when you i...

Страница 12: ...dly yellow from left to right for about 3 seconds indicating that the unit is performing a self diagnostic TAPE MOTION DRIVE ERROR TAPE ERROR CLEANING REQUEST All green flashing Firmware update All green lit Ejection inhibited only when pressing the eject button Orange flashing Tape being accessed write Drive error Media error Cleaning error Orange lit Media error Yellow flashing Tape being access...

Страница 13: ...nd Ventilation Holes Be careful not to block the ventilation holes If you do the unit may overheat resulting in damage D AC IN Connector Connect the power cable appropriate for your country to this connector E Ventilation Holes Be careful not to block the ventilation holes If you do the drive in the unit may overheat resulting in damage F SCSI Connector 1 7 SCSI Connector 2 Connect the SCSI bus ca...

Страница 14: ... resulting in damage E FC Status Indicator When the fibre channel connection is normal the indicator is off When the unit is communicating with the host computer this indicator lights green When there is a connection error the indicator lights orange In this case reconnect the cable or change it if necessary F Loop ID Jumpers These jumpers are functional when the topology is arbitrated loop For de...

Страница 15: ...about setting the DIP switches see Setting the DIP Switches on page 19 C Air Filter Unit Be careful not to block the ventilation holes of the air filter unit If you do the S AIT Tape Drive Unit may overheat resulting in damage Moreover periodically clean the air filter unit with a vacuum cleaner monthly cleanings recommended and replace it yearly For details about how to replace the air filter uni...

Страница 16: ...echnical support B Serial number The serial number is located on the bottom of the unit together with the model number Refer to the serial and model numbers on the label when seeking technical support C Number returned to the interface command The number which is returned to the interface command is located on the rear of the unit This is the serial number reported by the application software you ...

Страница 17: ...allation and setup procedures may vary slightly depending on your system Unpacking Note You will need the box and packing materials if you wish to move or transport the unit Retain them for future use 1 Remove the unit from the box as indicated below Remove the packing materials such as plastic covers and tapes 2 Inspect the unit for shipping damage If there is damage do not use the unit Report th...

Страница 18: ...he above other items may be included in the package All the items included with the S AIT Tape Drive unit are indicated on the package Preparing the Host Computer Prepare the host computer before installing the S AIT Tape Drive Unit 1 Make sure that a SCSI host adapter card or Fibre Channel host bus adapter FC HBA is installed in the host computer 2 Install all the necessary software supporting th...

Страница 19: ...gs of the DIP switches is as follows DC Control 1 ON Compression is enabled DC Control 2 OFF The host can control compression If necessary change the settings as follows Caution Before removing the access cover to change DIP switch settings of the S AIT Tape Drive Unit turn off the unit and disconnect the power cable 1 Make sure that the unit is off 2 Remove the two screws with a screwdriver and r...

Страница 20: ...FF SW6 Reserved OFF SW7 DC Control 1 ON SW8 DC Control 2 OFF SWB settings Common SW1 Reserved OFF SW2 Reserved OFF SW3 Reserved OFF SW4 Reserved OFF SW5 Reserved OFF SW6 Reserved OFF SW7 Reserved OFF SW8 Reserved OFF DC Control 1 DC Control 2 Definition OFF OFF Compression disabled The host can control compression OFF ON Compression disabled The host cannot control compression ON OFF Compression e...

Страница 21: ...ace model proceed to Setting the Loop ID SAITe1300 F only on page 23 Block Size Definition OFF Default is 512 byte block size fix mode ON Default is variable mode Immediate WFM Definition OFF Enable Immed bit field in WRITE FILEMARKS command ON Ignore Immed bit field and always return good status immediately UA Control Definition OFF Enable to report UnitAttention UA sense ON Disable to report Uni...

Страница 22: ...15 or F to 8 lowest The SCSI ID must be different from the IDs of other peripherals on the SCSI bus Do not select the SCSI ID of the SCSI host adapter card The priority of this ID is usually higher than that of any device on the SCSI bus Generally the SCSI ID of the host adapter is 7 Perform this setting before turning on the unit 1 Before changing the SCSI ID turn off the unit 2 Press the button ...

Страница 23: ...are disabled acquisition of AL_PA through LIHA is not performed so AL_PA is acquired from LISA Loop Initialization Soft Assigned Caution Turn off the unit before setting the Loop ID with the loop ID jumpers Failing to do so may result in damage Do not touch the fibre channel or jumper connectors of the unit when it is on Doing so may result in damage LOOP ID 2 1 0 LOOP ID 0 LOOP ID 1 LOOP ID 2 LOO...

Страница 24: ...4 100 34 0F 15 CE 3A 58 7A 65 101 33 10 16 CD 3B 59 79 66 102 32 11 17 CC 3C 60 76 67 103 31 12 18 CB 3D 61 75 68 104 2E 13 19 CA 3E 62 74 69 105 2D 14 20 C9 3F 63 73 6A 106 2C 15 21 C7 40 64 72 6B 107 2B 16 22 C6 41 65 71 6C 108 2A 17 23 C5 42 66 6E 6D 109 29 18 24 C3 43 67 6D 6E 110 27 19 25 BC 44 68 6C 6F 111 26 1A 26 BA 45 69 6B 70 112 25 1B 27 B9 46 70 6A 71 113 23 1C 28 B6 47 71 69 72 114 1F...

Страница 25: ...AC power outlet Make sure that you leave gap of about 150 mm 5 9 in behind the rear of the unit to allow air to circulate Recommended positioning of the unit Always position the unit horizontally Away from moving air such as fans open windows or air conditioners Away from devices such as facsimiles to avoid toner and paper dust The S AIT Tape Drive Unit should not be stacked Do not place anything ...

Страница 26: ...irmware that allows the S AIT Tape Drive Unit to interact with a variety of hosts If your software requires it install the appropriate device driver for your system from the supplied CD ROM Refer to the instructions on the CD ROM to install device drivers The latest device drivers and documentation for the S AIT Tape Drive Units are available online Contact your dealer for details or visit the Son...

Страница 27: ... make sure that you connect the supplied terminator to the open connector Make sure that the SCSI connectors are securely connected With LVD Low Voltage Differential SCSI make the total length of the SCSI cable internal and external connecting the host computer and the device at the end of the SCSI bus shorter than 12 m 39 4 ft On an LVD bus with a single device make this length shorter than 25 m ...

Страница 28: ... the SCSI bus connect the terminator to the last device on the bus then issue the host command to resume operation Notes The total length of the SCSI cables between the host computer and the last device should be less than 12 m 39 4 ft The SAITe1300 S internal cable length is 25 cm 9 8 in If the SAITe1300 S is the last device on the SCSI bus make sure that you connect the supplied terminator to th...

Страница 29: ...fications Duplex LC Fibre Channel connectors 50 125 µm multimode optical fiber cable Caution If your interface and optical fiber cable are different types the unit may not operate correctly when connected Turn off the unit when connecting or disconnecting a cable to the fibre channel connector Failing to do so may result in damage Never touch the fibre channel connector of the unit when the unit i...

Страница 30: ... Drive Unit to the Host Configure the S AIT Tape Drive Unit as follows 1 Turn on the S AIT Tape Drive Unit For details see Turning the Unit On or Off on page 31 2 To configure the unit for use refer to the documentation of the host computer and software ...

Страница 31: ...ter3 Operation Overview This chapter describes how to turn the unit on and off as well as how to insert and eject cartridges Turning the Unit On or Off Turning On the Unit 1 Press the DOOR button to unlock and open the front door ...

Страница 32: ...green or yellow Caution If the POWER indicator flashes when the unit starts the cooling fan of the unit may be malfunctioning If this is the case verify that the cooling fan on the rear is operating normally If it is not contact your Sony service center If the status indicators do not behave as described above see chapter 1 Do not push down the front door when it is opened Doing so may result in d...

Страница 33: ...t write protected and prepare them for use Verify whether the write protect switch is in the write enable position For details see Setting the Write protect Switch on page 38 Inserting a Cartridge 1 Press the DOOR button to unlock and open the front door 2 Press the power switch on the front panel The POWER indicator lights green and the TAPE MOTION DRIVE ERROR TAPE ERROR and CLEANING REQUEST indi...

Страница 34: ...g and writing of tapes For details about the status of the unit as shown by the indicators on the front of the unit see chapter 1 Removing a Cartridge When the cartridge is automatically ejected by your software 1 Press the DOOR button to unlock and open the front door 2 Remove the cartridge from the unit and close the door When you eject the cartridge manually 1 Press the DOOR button to unlock an...

Страница 35: ...f cartridges such as LTO Ultrium SDLT or DLT Data Cartridge S AIT data cartridges contain a half inch AME Advanced Metal Evaporated tape When processing the tape the S AIT Tape Drive Unit uses an advanced helical scan recording technology known for its high data density outstanding data transfer performance as well as its reliability and durability The cartridges also incorporate a built in Remote...

Страница 36: ...drive C Label Area Area where you can affix labels to identify your S AIT data cartridges Note Make sure that you affix your label squarely into the label area as protruding labels can cause loading and ejection problems D Write protect Switch This switch is used to prevent data from being written to the tape For details see Setting the Write protect Switch on page 38 Note The Sony S AIT Data Cart...

Страница 37: ...ot close the reel lock as this may cause loading problems G Positioning Hole Used by the unit to determine the position of the cartridge in the unit Caution Do not close the positioning hole as this may cause loading problems H Leader Block The tape is attached to the leader block When you insert a cartridge into the unit the leader block is extracted from the cartridge loaded onto a non removable...

Страница 38: ...ng hole as this may cause loading problems Setting the Write protect Switch The position of the write protect switch on the cartridge determines whether you can write to the tape If you do not want to write to the tape slide the switch in the direction of the arrow as illustrated below Cleaning Cartridge Use a Sony S AIT Cleaning Cartridge SAIT1 CL to clean the drive heads The unit determines when...

Страница 39: ... physical damage Never affix labels elsewhere than on the repressed label area as doing so may cause loading problems The write protect switch of cartridges is used to prevent writing to the tape by accident If you do not want to write to a cartridge slide it to the write protect position For details see Setting the Write protect Switch on page 38 If the S AIT Tape Drive Unit is used in a high hum...

Страница 40: ...perating environment Temperature 5 to 35 C 41 to 95 F Relative humidity 20 to 80 non condensing Wet bulb temperature 26 C 79 F Storage environment Temperature 16 to 32 C 61 to 90 F Relative humidity 20 to 60 non condensing Wet bulb temperature 26 C 79 F Transport environment When packed Temperature 23 to 48 C 9 to 118 F Relative humidity 5 to 80 non condensing Wet bulb temperature 26 C 79 F ...

Страница 41: ...to the unit The unit loads the cartridge and cleans the heads During the cleaning cycle the CLEANING REQUEST indicator lights yellow 2 When cleaning ends the unit ejects the cartridge and the CLEANING REQUEST indicator goes out Note An S AIT cleaning cartridge is good for 50 uses The cleaning cartridge R MIC keeps track of how many times the cartridge is used When the cleaning cartridge reaches th...

Страница 42: ...at you clean the air filter unit once a month with a vacuum cleaner 1 Prepare a new air filter unit 2 Turn off the unit 3 Disconnect all cables from the unit 4 Turn the unit upside down There are three latches on the air filter unit 5 Push the air filter as illustrated below to release the latch and then lift it 6 Repeat steps 4 and 5 in reverse to install the new air filter unit ...

Страница 43: ...the SCSI bus To obtain up to date firmware and installation instructions contact your dealer or visit the Sony Web site http www sony net Products storagesolution Taking Care of the Unit Safety Power Only use 100 V 240 V AC Avoid plugging the unit to the same power outlet as high current equipment such as copiers or shredders Power Cable Precautions Do not crush the cable or place heavy objects on...

Страница 44: ...it is moved from a cool to a warm place or if the room temperature suddenly rises moisture may condense inside the case After a sudden change in temperature wait at least one hour before turning on the unit Turning on the unit with condensation inside and inserting a cartridge may damage the tape or the unit Abnormal Occurrences If the unit behaves abnormally or it begins to smell or smoke unplug ...

Страница 45: ...eir receptacles and if necessary tighten the screws until they are firmly seated For details see Connecting the SCSI Bus Cable SAITe1300 S only on page 27 Verify that the SCSI bus is terminated correctly For details see Connecting the SCSI Bus Cable SAITe1300 S only on page 27 Verify that all the connector pins are undamaged Remove the terminator and cable connectors and inspect them for bent rece...

Страница 46: ... that the Loop ID is set correctly For details see Setting the Loop ID SAITe1300 F only on page 23 Your software does not detect the unit Verify that your software supports the S AIT Tape Drive Unit For details about software that can be used on the S AIT Tape Drive Unit and supported operating systems contact your dealer Verify that the software is correctly installed and set up on the host compu...

Страница 47: ...Search time Average 70 seconds 1 Compression ratios vary according to the type of data 2 The transfer rate may differ according to your system performance 3 Does not include retry time Environmental Specifications Operating Temperature range 5 to 35 C 41 to 95 F Humidity range 20 to 80 non condensing Maximum wet bulb temperature 26 C 79 F Non operating Temperature range 40 to 70 C 40 to 158 F Humi...

Страница 48: ... Noise level Streaming read write 50 dB A External dimensions 210 86 372 mm W H D excluding protrusions 8 3 3 4 14 6 in Mass 7 kg 15 4 lb In the interest of product improvement specifications are subject to change without notice Options S AIT data cartridge 500 GB uncompressed 1300 GB compressed 600 m 1968 ft tape Model SAIT1 500 S AIT cleaning cartridge Model SAIT1 CL Rack mount kit Model ACY RKS...

Страница 49: ...omputer 18 30 I Indicators 12 Inserting cartridge 33 Installation 17 25 Installing device drivers 26 L Label 16 Loop ID 23 M Model number 16 O Operation 31 Optical fiber cable 29 Options 48 P Package contents 18 Performance 47 Positioning 25 Power 48 Power cable 26 Preparing host computer 18 R Removing cartridge 34 Reset 43 S Safety 43 S AIT technology 7 SCSI bus cable 27 SCSI ID 22 Serial number ...

Страница 50: ...Sony Corporation For information about the S AIT Tape Drive Unit contact your reseller ...

Отзывы: