4-4
VPL-PX20/PX30
15. Rest the CONTRAST to 80.
16. Connect the oscilloscope to TP605 on the C board.
17. Enter the WB ADJUST HIGH by the menu.
18. Adjust the DC level of signal’s 87.5 IRE section for 6.0
±
0.05 Vdc with GAIN B .
19. Connect the oscilloscope to TP602 on the C board.
20. Adjust the DC level of signal’s 87.5 IRE section for
6.0
±
0.05 Vdc with GAIN G.
21. Connect the oscilloscope to TP608 on the C board.
22. Adjust the DC level of signal’s 87.5 IRE section for
6.0
±
0.05 Vdc with GAIN G and adjust the lower side
of the 12.5 IRE section of the signal for 3.0
±
0.05Vdc
with 13.VAMP/SUB CON B.
23. Connect the oscilloscope to TP608 on the C board.
24. Adjust the DC level of signal’s 87.5 IRE section for
6.0
±
0.05 Vdc with GAIN R and adjust the DC level
of signal’s 12.5 IRE section for 3.0
±
0.05 Vdc with
BIAS R.
25. Select the SAVE TO MEMORY from the W/B
ADJUST page of the menu, and press the ENTER key
to save the data.
4-4-7. W/B LOW Adjustments
1.
Enter the RGB WB LOW by the menu.
2.
Copy the adjusted value of the HIGH mode to the
R/G/B BIAS.
3.
Enter the following value in the R/G/B GAIN.
R GAIN: HIGH mode
+
5
G GAIN: HIGH mode
_
5
B GAIN: HIGH mode
_
15
4.
Select the SAVE TO MEMORY from the W/B
ADJUST page of the menu, and press the ENTER key
to save the data.
5.
Enter the OTHER of the device adjust of the menu.
6.
Reset 06 3D GAMMA/THROUGH: 1 to 06 3D
GAMMA/THROUGH: 0.
7.
Reset 07 3D GAMMA/SW: 0 to 07 3D GAMMA/SW:
1.
8.
Select the SAVE TO MEMORY from the Device
adjust page of the menu, and press the ENTER key to
save the data.
4-4-8. Component Y Level Adjustment
1.
Input the Component Y signal to INPUT-A (5BNC),
and select the COMPONENT by INPUT-A of the SET
SETTING.
2.
Connect the oscilloscope to TP605 on the C board.
3.
Enter the OTHER of the device adjust of the menu.
4.
Set 06 3D GAMMA/THROUGH: 0 to 06 3D
GAMMA/THROUGH: 1.
5.
Set 07 3D GAMMA/SW: 1 to 07 3D GAMMA/SW: 0.
6.
Enter the WB ADJUST HIGN from the menu.
7.
Adjust the 100 IRE section of the signal for 6.1
±
0.05
Vdc with GAIN B and adjust the 12.5 IRE section of
the signal for 6.1
±
0.05 Vdc with BIAS B.
8.
Connect the oscilloscope to TP602 on the C board.
9.
Adjust the 100 IRE section of the signal for 6.1
±
0.05
Vdc with GAIN G and adjust the 100 IRE section of
the signal for 3.0
±
0.05 Vdc with BIAS G
10. Connect the oscilloscope to TP608 on the C board.
6.0 0.05Vdc
0V
3.0 0.05Vdc
0
100 IRE
12.5 IRE
Содержание RM-PJM610
Страница 153: ...9 20 9 20 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 ...
Страница 161: ...9 28 9 28 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 C B SIDE SUFFIX 11 C A SIDE SUFFIX 11 ...
Страница 165: ...9 32 9 32 A B C D E F G H 1 2 3 4 5 VPL PX20 PX30 Y S NF NR Y S NF NR ...
Страница 177: ...Sony Corporation B P Company English 99KZ08111 1 Printed in Japan 1999 11 9 929 667 01 ...