74
Warning Lamps
26. Warning Lamps
References:
•
PCM-3324S Operation Manual, “4-2 Warning Lamps”
•
PCM-3348HR Operation Manual, “12-2 Warning Lamps”
26-1. If the FORMAT MISMATCH Lamp Lights Repeatedly
If the FORMAT MISMATCH lamp lights, carry out the following diagnostic
procedure.
26-2. If the EMPHASIS MISMATCH Lamp Lights Repeatedly
If the emphasis information recorded on a channel which is in the recording ready
state is different from the EMPHASIS switch setting, the EMPHASIS MISMATCH
lamp lights. During recording, the emphasis information follows the EMPHASIS
switch setting, and therefore care is needed when recording repeatedly on a tape
being used for playback. If you continue recording while the EMPHASIS
MISMATCH lamp is lit, the recording will be carried out with different emphasis
settings from those recorded on the tape.
No
Yes
No
Yes
Yes
No
Yes
No
Are you using a blank tape?
Either the tape is DASH
format, but is of the
wrong version, or the
tape is faulty.
Use a DASH or DASH
PLUS format tape.
Load the tape
correctly.
Carry out prestriping
first.
The Fs ID code reader
circuit is faulty.
Does the FORMAT
MISMATCH lamp light?
Try using another
prestriped blank tape.
Are you using a DASH or
DASH PLUS format tape?
Is the tape loaded upside down?