73
SYNC CLOCK lamps
These indicate which reference signal is being used for synchronization.
INT: Internal master clock
EXT: Signal input via the WORD SYNC INPUT connector of the PCM recorder
DI: Signal input via the AES/EBU D-I connector of the PCM recorder
REMOTE 3: Signal input via the RM-3324 or RM-3348HR
VIDEO: Composite video signal input to the REFERENCE VIDEO INPUT
connector on the rear panel of the PCM recorder.
EXT (external) CLOCK ERROR lamp
This lights in the following cases:
•
When the PCM recorder’s SYNC CLOCK switch is set other than to INT and
external synchronization is not possible
•
When the PCM recorder’s SYNC CLOCK switch is set other than to INT and the
selected reference signal is not input
•
When the PCM recorder’s SYNC CLOCK switch is set to REMOTE 3 and the
sector-based synchronization is not possible
Even if the operation is normal, this lamp flashes for several seconds after the
reference signal is switched.
EMPHASIS MISMATCH lamp
This lights when the emphasis information recorded on a tape does not agree with
the EMPHASIS or EMPH switch setting on the PCM recorder.
SYSTEM WARNING lamp
This lamp lights when there are particular combinations of settings on the PCM
recorder.
SYSTEM ALARM lamp
This lamp lights when there is a fault on the PCM recorder.
Main Unit Status Lamps