22
14. Backup Copy Function
Copying the CTL and digital audio signals
When using PCM-3324S with RM-3324 or PCM-3348HR with RM-3348HR
Connections
Power off all units before making the connections.
Connections for copying the CTL and digital audio signals using RM-3324/3348HR
Procedure
1
Mount the original tape on the player unit, and set the MASTER SAFE switch
to the ON position.
2
Mount a blank tape on the recorder unit, and set the switches and buttons as
follows:
•
MASTER SAFE switch: OFF
•
SAMPLING FREQ (Fs) switch: Sampling frequency of the original tape
•
TIMER MODE button: CTL ABSOLUTE
•
REC MODE switch: ADVANCE
•
INPUT SELECT switch: DIGITAL
Backup Copy Function
A1
OUTPUT
A1
INPUT
A2
OUTPUT
A2
INPUT
TIME CODE
OUTPUT
TIME CODE
INPUT
SDIF-2
(BALANCE)
OUTPUT
SDIF-2
(BALANCE)
INPUT
WORD SYNC
IN
WORD SYNC
OUT
TAPE
RECORDER
REMOTE-3
TAPE
RECORDER
REMOTE-3
IEEE Std.
488-1978
IEEE Std.
488-1978
SECTOR
SYNC
IN
SECTOR
SYNC
OUT
SECTOR
ADDRESS
IN
SECTOR
ADDRESS
OUT
PCM-3324S/
PCM-3348HR
(Recorder unit)
Word sync signal
Time code signal
Analog audio signal
Analog audio signal
PCM-3324S/
PCM-3348HR
(Player unit)
Digital audio signal
RM-3324/
RM-3348HR
RM-3324/
RM-3348HR
Sector sync signal
Sector address signal
IEEE-488 bus signal