For Authorized Servicer
5-10. Acceleration sensor (G-Sensor)
Diagnosis APP
[ver X.XX.XX]
G-Sensor
Display acceleration data
Execute the Self test
Screen display
5-10-1. Acceleration data display
(Display acceleration data)
It can be check the acceleration sensor data.
Procedure:
1. Press the [+] or [–] button to select the “G-Sensor”, and press the
[
u
] or [
>
] button to enter the minor item.
2. Press the [+] or [–] button to select the “Display acceleration
data”.
3. Press the [
u
] button, the acceleration sensor data (X/Y/Z axis)
screen is displayed.
(Displayed characters/values in the following
fi
gure are exam-
ple)
G-Sensor
(GSN ACCD command)
Acceleration Data
acceleration X :
[–0.206]
acceleration Y :
[0.070]
acceleration Z :
[9.611]
Screen display
4. Press the [
u
] button in the state of step 3, updates the accelera-
tion sensor data display.
5. Switch the [HOLD] switch in the order of OFF
t
ON, or ON
t
OFF
t
ON, to return to minor item selection screen.
5-10-2. Self test execution (Execute the Self test)
It can be execute a self test of the acceleration sensor.
Procedure:
1. Press the [+] or [–] button to select the “G-Sensor”, and press the
[
u
] or [
>
] button to enter the minor item.
2. Press the [+] or [–] button to select the “Execute the Self test”.
3. Press the [
u
] button, the self test screen is displayed.
(Displayed characters/values in the following
fi
gure are exam-
ple)
G-Sensor
(GSN SELF command)
Self test
>>> start
Screen display
4. When
the
[
u
] button is pressed and the self test ends normally,
the result of “OK” is displayed.
(Displayed characters/values in the following
fi
gure are exam-
ple)
Note:
“NG” is displayed when there is an error, and “ERROR” is displayed
when there is no response from the device.
G-Sensor
(GSN SELF command)
Self test
acceleration diff X :
[15000]
acceleration diff Y :
[15000]
acceleration diff Z :
[15000]
>>> OK
Screen display
5. Switch the [HOLD] switch in the order of OFF
t
ON, or ON
t
OFF
t
ON, to return to minor item selection screen.
5-11. USB
(USB)
Note:
This major item is not used for the servicing.
SYS SET
2020/02/27 22:57:21 (GMT+09:00)