2-9. CAP BOTTOM ASSY BLOCK
Note of installing the HP FPC
Be careful following points when bending of the HP FPC, installing
to the connector.
Don’t press with the nails of the fingertip or bend with the tweezers.
When inserting the HP FPC to the connector, insert it straight into the
interior.
When locking the connector of the HP FPC, press the center of the
lock plate.
Check the connector of the HP FPC is completely locked or connected.
1
Peel off the key FPC from the sheet adhesive OBC.
Note
1:
When installing the key FPC, don’t press with
the nails of the fingertip or bend with the tweezers.
Note
2:
When installing the key FPC, align the two
bosses and two holes.
5
two screws (NDS-EL)
(M1.4) (L = 4.0 mm)
cabinet block
connector
(CN1001)
2
sheet (ENT)
boss
key FPC
hole
sheet
adhesive
OBC
rib
rib
groove
groove
hole
pin strap (shaft)
8
cap bottom assy block
Note
3:
When installing the cap bottom assy
block, align the pin strap (shaft) and
hole, two grooves and two ribs.
7
Remove the cap bottom assy
block in the direction of the
arrow.
6
Lift up the cap bottom assy
block in the direction of the
arrow.
terminal side
HP FPC
connector
(CN1001)
4
Draw out the HP FPC
from the connector.
3
Unlock the connector (CN1001).
bottom side
top side
bottom side
rear side
SYS SET