15
MZ-R701/R701DPC
• Description of indication history
History code number
Description
1
The first error
N
The last error
N1
One error before the last
N2
Two errors before the last
R_
Total recording time
4-9. Reset the Error Display Code
After servicing, reset the error display code.
• Setting method of reset the error display code
1. Setting the test mode (see page 12).
2. Press
[ENTER]
key activates the self-diagnosis result display
mode.
3. To reset the error display code, press the
X
key (2 times) when
the code is displayed (except “R_
****
”).
(All the data on the 1, N, N1 and N2 will be reset)
• Description of error indication codes
Problem
Indication code
Meaning of code
Simple display
Description
No error
00
No error
---
No error
01
Illegal access target
Adrs
Attempt to access an abnormal address
address was specified
Servo system error
02
High temperature
Temp
High temperature
03
Focus error
Fcus
Disordered focus
04
Spindle error
Spdl
Abnormal rotation of disc
TOC error
11
TOC error
TOC
Faulty TOC contents
12
Data reading error
Data
Data could not be read at SYNC
Power supply system error
22
Low battery
LBat
Momentary interruption detected
31
Offset error
Ofst
Offset error
32
Focus error
ABCD
Focus error
ABCD offset error
ABCD offset error
Offset system error
33
Tracking error
TE
Tracking error
Offset error
Offset error
34
X1 tracking error
X1TE
X1 tracking error
Offset error
Offset error