5-8. Overall Adjustment Mode
• Configuration of overall adjustment
Note:
Adjust the CD first, when performing adjustment.
.
key
>
key
N
key
N
key
Protect switch
ON
Protect switch
OFF
x
key
x
key
x
key
x
key
x
key
x
key
NG item exists
or
x
key
Overall Adjustment Mode
(Title Display)
CD Overall
Adjusting
MO Overall
Adjusting
CD Overall
Adjustment
OK
MO Overall
Adjustment
OK
CD Overall
Adjustment
NG
NG item exists
or
x
key
MO Overall
Adjustment
NG
Electrical
Offset
Adjustment
Power Supply
Adjustment
Auto Item Feed
ENTER
key
END SEARCH
key
Test Mode (Display Check Mode)
All item
OK
• Overall adjustment mode (Title display)
• Electrical offset adjusting method
Caution: The electrical offset adjustment must be made with no
disc loaded.
1. Make sure that the power supply voltage is 3V.
2. Set the test mode (see page 12).
3. Press the
.
or
[VOL --]
key to activate the overall adjustment
mode.
4. Press the
[ENTER]
key.
5. Electrical offset adjustment is over, if the following display
appears.
This set LCD display
0 00
Assy
: (Disc mark) At end power supply adjustment: Outside lit
At end of electrical offset adj.:inside lit
Note: On the set having microcomputer version 1.000, the disc
mark is displayed on the set LCD only.
: Left side = MO overall adjustment information
F : MO overall adjustment completed
1 : Manual adjustment exists (overall adj. not completed)
0 : Not adjusted
Right side = CD overall adjustment information
F : CD overall adjustment completed
1 : Manual adjustment exists (overall adj. not completed)
0 : Not adjusted
This set LCD display
0 00
Assy 11
This set LCD display
0 35
Ofst
: Adjusted value
This set LCD display
0 00
OfstOK