2-16 (E)
LMT-300
Example of restoration
1. Check from a DOS command line.
Entry from DOS command line and result
2. The contents of entry after browser start are as described below.
Check that the operation above is completed.
Restart the power and complete.
2-3-3. Connection to System
Make a connection to the system in the procedure below when this unit was installed in an SRX-R320
system after board replacement and data transition are completed.
1. Connect all disconnected connection cables to the former places where they were connected.
2. Turn on the system power and start the system.
3. Set the Time using SRX-R320. (Refer to the “Operating Instructions” of SRX-R320.)
4. Set the Marriage using SRX-R320. (Refer to the “Operating Instructions” of SRX-R320.)
5. Set the Security using SRX-R320 or SMSC. (Refer to the “Operating Instructions” of SRX-R320 or
the SMSC Manual.)
6. Check that the Status Light lamp properly lights (in green).
c:\>ping <LMT300 IP Address>
c:\temp >putsetup.bat 192.168.1.10
c:\temp >echo off
c:\temp >ftp -s:putsetup.ftp
ftp> open 192.168.1.10
Connected to 192.168.1.10.
220 Welcome to blah FTP service.
User (192.168.1.10:(none)):
331 Please specify the password.
230 Login successful.
ftp> bin
200 Switching to Binary mode.
ftp> put setupdata
200 PORT command successful. Consider using PASV.
150 Ok to send data.
226 File receive OK.
ftp: 2289 bytes sent in 0.08Seconds 29349.05Kbytes/sec.
ftp> quit
221 Goodbye.
c:\temp >
URL http://192.168.1.10
ID:user
Password:passwd
File name Fputsetup.elp
Upload
Software Update Complete !!