2-13 (E)
LMT-300
c:\temp>getsetup 192.168.1.10
6. Enter “getstup.bat 192.168.1.10”.
(“192.168.1.10” is the IP address of this unit.)
Data begins to be automatically delivered from the inside of this unit. It is created in PC as a memory
data
fi
le. (File name: setupdata)
n
A memory data
fi
le is created in the folder where getsetup.bat was executed.
7. Perform the setting for the auto rebuild of network setting.
n
When the PU-131 board assembly is replaced, the MAC address is changed. So the rebuild of the
network setting is required.
(1) Disconnect the Ethernet cable from the DATA IN terminal.
(2) Connect the Ethernet cable to the CTRL IN terminal of this unit.
(3) Log in to the SMS server using ssh.
n
For ID: SMS Password, contact your local Sony Sales Of
fi
ce/Service Center.
(4) Execute the following command.
Command: # rm/home/sms/lock/smsnet-setup.lock
(5) Shut down the system.
Example of backup execution
1. The contents of entry after browser start are as described below.
Check that the operation below is completed.
2. Check from a DOS command line.
Check that a response exists. Check the IP setting of this unit or PC when no response exists.
URL http://192.168.1.10 <LMT300 IP Address>
File name Fgetsetup.elp
Upload
Software Update Complete !!
c:\>ping 192.168.1.10
Содержание LMT-300
Страница 1: ...MEDIA BLOCK LMT 300 SERVICE MANUAL 1st Edition Revised 4 ...
Страница 4: ......
Страница 8: ......
Страница 28: ......
Страница 46: ......
Страница 78: ......
Страница 92: ...Sony Corporation LMT 300 SY J E 9 968 672 05 Printed in Japan 2012 7 32 2009 ...