6-59
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
28. White Defect Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is “00”
or “02” to “FF”.
Note 1:
Perform “HS White Defect Adjustment” before this ad-
justment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “25” to
“50”. (Note 6)
4
6
07
Check the data is “04”.
5
6
D0
06
6
6
01
21
Press PAUSE (Write) button.
7
Wait for 10 seconds.
8
6
02
Check the data changes to
“01”.
9
6
D3
Check the data is “00” or
“02” to “FF”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
If the data is other than “25” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
29. White Defect Adjustment (FD white point)
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “25” to
“50”. (Note 6)
4
6
07
Check the data is “04”.
5
6
D0
0C
6
6
01
21
Press PAUSE (Write) button.
7
6
02
Check the data changes to
“01”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
If the data is other than “25” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Ver. 1.2 2008.04