6-38
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
06
3
8
19
03
(68)
Press PAUSE (Write) button.
4
8
90
40
(68)
Press PAUSE (Write) button.
5
0
10
00
6
6
02
Check the data is “00”.
(Note 4)
7
6
4D
40
8
6
64
04
9
6
01
13
Press PAUSE (Write) button.
10
Wait for 2 seconds.
11
Place ND filter on the lens so
that the optimum image is
obtain.
12
6
01
29
Press PAUSE (Write) button.
(Note 5)
13
Wait for 10 seconds.
14
6
02
Check the data changes to “01”.
15
6
0C
Check the data is “00”.
16
0
10
06
17
F
2F
Check the data is “00” to “09”.
(6F)
18
0
10
00
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 20 to 3F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
01
00
Press PAUSE (Write) button.
4
6
4D
00
5
6
64
00
6
0
10
06
7
8
90
00
(68)
Press PAUSE (Write) button.
8
8
19
07
(68)
Press PAUSE (Write) button.
9
0
10
00
10
0
01
00
11
Perform “Flange Back
Check”.
7-2. Flange Back Adjustment (2)
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
20 to 3F
Specified value
Data of page: 6F, address: 2F is“00” to “09”
Data of page: 6, address: 0C is“00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)