6-34
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
5.
Differential Gain Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the dispersion of between the channels of CMOS imager.
Subject
Clear chart (All white) (Note 1)
Adjustment Page
6E
Adjustment Address
00 to B3
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
If reading/writing data on pages 6E set data: 06 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM ..................................................................... TELE end
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
3
6
2C
01
4
6
40
01
5
6
D0
60
6
6
D2
01
7
6
D3
01
8
6
D6
10
9
6
01
F5
Press PAUSE (Write) button.
(Note 4)
10
Wait for 3 seconds.
11
6
02
Check the data changes to
“01”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6E, address: 00 to B3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
2C
00
3
6
40
00
4
0
01
00