1-4
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
E
E
E
E
E
E
E
E
E
E
Block
Function
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Detailed
Code
1
0
1
1
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
Symptom/State
Zoom operations fault.
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur
simultaneously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch).
Shift lens overheating (Yaw).
Abnormality of thermistor.
Self-diagnosis Code
Repaired b
y:
Correction
Inspect the zoom MR sensor of lens block (Pin
w;
,
wa
of CN5301
on the LD-229 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC5404 on
the LD-229 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE7202 on the CM-077
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE7201 on the CM-077
board) peripheral circuits.
Refer to [
1-6-1
. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5703 on the LD-229 board).
Refer to [
1-6-2
. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred].
Refer to [
1-6-3
. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [
1-6-4
. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [
1-6-5
. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Ver. 1.3 2008.12
The changed portions from
Ver. 1.2 are shown in blue.