A
ppe
ndix
e
s
109
Warning System
Warning System
When an error is detected immediately after the system is
powered on, or during operation, the control panel display
and the tally indicator
alert you to the error.
In addition, warning and alarm tones are output from the
EARPHONES jack.
Notes
• Warning tones are not output unless BEEP(PHONE)
>WARN in the AUDIO Setup menu
to HIGH or LOW.
• Alarm tones are not output unless BEEP(PHONE)
>ALARM in the AUDIO Setup menu
set to HIGH or LOW.
The following table lists the types of warning and alarm
tones, and the state of the tally indicator, for warnings,
errors, and other conditions which require your attention,
such as tape end, near tape end, battery exhausted, and
battery almost exhausted, along with the steps to take when
they occur.
Warning tones
: 1 beep/
second
: 4 beeps/
second
:
Continuous
tone
Alarm tones
: 1 beep/
second
: 4 beeps/
second
:
Continuous
tone
Tally indicator
: 1 flash/second
: 4 flashes/
second
Description
VTR (SRW-1)
behavior
Steps to take
—
—
—
A warning message
condition occurred.
(Excepting “Servo
lock lost during
recording”
described below.)
Continues
operation.
Check the warning
message, and
resolve the
condition, referring
to the “Description”
column in the table
of “Warning
messages”
a)
—
b)
Servo lock lost
during recording.
Recording
continues, but the
results may be
invalid.
Turn off the power
and contact a Sony
service
representative.
—
An error occurred
(Excepting “0050
NO REC RF”).
Continues
operation or stops,
depending on the
type of error.
Check the warning
message, and
resolve the
condition, referring
to the “Description”
column in the table
of “Error
messages”
. Or contact a
Sony service
representative.
If a slack error
occurs, refer to the
maintenance
manual and remove
the cassette, or
contact a Sony
service
representative.
a)
—
b)
“0050 NO REC RF”
error occurred. RF
signals cannot be
detected. Video
head clogging or
failure in recording
system.
Recording
continues, but the
results may be
invalid.
Clean the video
heads. If recording
fails after head
cleaning, turn off
the power and
contact a Sony
service
representative.
Содержание HKSR-101