Error Messages and Warning Messages
Warning messages
Code
Message
Description
SRW-1 warning
a)
SRPC-1 warning
b)
0001
—
PB FREQ MISMATCH
System frequency of this system does not match
system frequency on the tape.
0004
—
NO PB LTC
Playback LTC cannot be detected.
0005
—
NO PB VITC
Playback VITC cannot be detected.
0007
—
REC INHIBIT MODE
The system cannot record because of a record
inhibit menu setting. Or the tape is not formatted for
recording.
0008
—
INVALID FMT CONV
Format conversion is not possible with the current
settings.
0009
0109
TEMPERATURE LOW
The temperature inside the unit is lower than the
specified values.
000C
010C
DC VOLTAGE LOW
DC voltage has fallen below the specified level.
000E
010E
TEMPERATURE HIGH
The temperature inside the unit has risen.
000F
—
VA MISSING
SRPC-1 is not connected.
—
010F
VTR MISSING
SRW-1 is not connected.
0010
—
TELEFILE FULL
Telefile memory is almost full. The next recording will
erase existing data, beginning with oldest.
0011
—
TELEFILE NO ROOM
Free memory in a Telefile has been completely
exhausted.
0013
—
TELEFILE FMT NG
Telefile format is invalid in 1 or more locations.
0014
—
TELEFILE RD FAIL
Telefile read failure occurred.
0015
—
TELEFILE WR FAIL
Telefile write failure occurred.
0016
—
TELEFILE WR INHI
Attempt to record was made when entire Telefile is
write inhibited.
0017
—
NO TELEFILE LABE
Telefile could not be recognized.
—
0121
PD PLL UNLOCK
The pull-down PLL could not be locked on the
selected reference signal. Input a correct reference
signal. Pull-down output is not supported for the
24PsF format. In this case, set REFERENCE
>MODE in the SYSTEM Setup menu to “Input”, or
after setting it to “EXT” set REFERENCE
>EXTERNAL to “HD”.
0022
0122
AUDIO PLL UNLOCK
Audio clock generator PLL is not locked to reference
video signal.
—
0124
NO HD REF
No HD reference signal is being input, even though
REFERENCE >EXTERNAL in the SYSTEM Setup
menu is set to HD or HD&SD.
—
0125
NO SD REF
No SD reference signal is being input, even though
REFERENCE >EXTERNAL in the SYSTEM Setup
menu is set to HD&SD or SD.
—
0126
HD&SD REF ASYNC
HD reference signal and SD reference signal are not
synchronized, even though REFERENCE
>EXTERNAL in the SYSTEM Setup menu is set to
HD&SD.
—
0128
REF SEL NOT GOOD
Reference signal selection is invalid.
—
012C
BAD HD REF
HD reference signal is invalid.
—
012D
BAD SD REF
SD reference signal is invalid.
0030
0130
NO SDI INPUT
When the optional HKSR-101 is installed, there is no
valid input to the selected VIDEO I/O connector.
0032
0132
INVALID SDI DATA
SDI input signal data is invalid.
Содержание HKSR-101