App
end
ix
e
s
104
Error Messages and Warning Messages
Error Messages and
Warning Messages
About Error Messages
When the system stops operating incorrectly because of an
internal error, a warning tone sounds and a popup window
appears in the display of the control panel with an error
message.
Only one message is displayed at one time, even if
multiple errors occur. But the number of current errors
appears at the bottom of the popup window.
When an error message appears
Eliminate the cause of the error, and power the system off
and on again. If the same error message appears again
when the system is powered on, contact a Sony service
representative.
To close the error message popup window
Press the HOME button or the BACK button on the control
panel.
If you press the HOME button, an error code appears in the
operation status and warnings section of the control panel
display
.
If you press the BACK button, the same error code appears
in the operation status and warnings section of the display
when you move back as far as the HOME screen.
The error code remains visible until the cause of the error
is eliminated.
Tape protection mode
To protect the tape and the mechanical parts of the SRW-
1, the servo control system automatically stops tape
transport and the drum motor and enters tape protection
mode when an error occurs.
Cassettes may not be inserted or ejected while the SRW-1
is in tape protection mode.
Note
If a cassette is stuck in the SRW-1 because of tape
protection mode, remove the tape manually, making sure
to power the system off before doing so.
See“To remove a cassette with the system powered off”
(page 39) for more information about how to remove a
cassette manually.
LOCAL
PB
21:46
1080
S59P
(29PsF)
4:2:2
IN: --:--:--:--
ANA
EMP
1
L R
ANA
EMP
2
L R
SDI
EMP
3
L R
SDI
EMP
4
L R
SDI
EMP
5
L R
SDI
EMP
6
L R
SDI
EMP
7
L R
SDI
EMP
8
L R
SDI
EMP
9
L R
SDI
EMP
10
L R
A/E
EMP
11
L R
A/E
EMP
12
L R
dB
0
-10
-20
-30
-60
TCR
OOOO
12.2V
REMAIN
CH.COND
18min
PLAY LOCK
RECINHI
LTC INTRP
DF
EXT-LK
KEYINHI
VTR OOOOO
00
H
00
M
00
S
00
F
ERROR
VTR:007F
VTR:007F
HUMID ERROR
HUMID ERROR
Humid Error
1 Error(s)/ 2 Warning(s)
PB
Example:
Popup window displaying error message “VTR:
007F HUMID ERROR” (condensation detected)
There is one current error.
There are two current warnings
.
To view the other messages, rotate the SELECT/ENTER dial
on the control panel.