Chapter 10
Setup Menus
10-10
Chapter 10 Setup Menus
10-4 Items in the Extended Setup Menu
The extended setup menu contains the following
items.
10-4 Items in the Extended Setup Menu
Item number Item name
Settings
101
SELECTION FOR
SEARCH DIAL ENABLE
Select how the unit enters the search mode.
DIAL :
Turning the search dial switches to search mode at all times except during
recording/editing.
KEY:
One of the JOG, SHUTTLE, and VAR buttons must be pressed to switch to
search mode.
102
MAXIMUM SPEED
Select the fast forward and rewind tape speed and also search mode speed
during tape playback.
MAX :
Perform fast forward, rewind, and search mode playback at the maximum
speeds.
MX/24:
Perform fast forward and rewind at the maximum speeds, and search
mode playback at up to 24 times normal speed.
MX/35:
Perform fast forward and rewind at the maximum speeds, and search
mode playback at up to 35 times normal speed.
×
24:
Perform fast forward and rewind at 24 times normal speed, and search
mode playback at up to 24 times normal speed.
×
35:
Perform fast forward and rewind at 35 times normal speed, and search
mode playback at up to 35 times normal speed.
Maximum fast forward and rewind speeds
HDCAM cassette: 50 times normal speed
Maximum search mode speeds
HDCAM cassette: 50 times normal speed
104
AUDIO MUTING TIME
Select the length of time for which audio muting occurs when the unit switches to
playback either from stopped or from still playback in the search mode.
OFF :
Set the audio muting time to zero (i.e. no muting).
0.1S to 1.0S:
Set the audio muting time from 0.1 second to 1.0 second, in 0.1-
second increments.
105
REFERENCE SYSTEM
ALARM
Select whether or not to display a warning when the video/audio reference signal
selected by the function menu item OUTREF, is not supplied or is out of phase
with the input video signal.
OFF:
No warning.
ON :
Flash the STOP button as a warning.
106
Select the capstan servo lock mode.
PANEL :
The capstan servo lock mode is determined by the function menu item
CAPSTN.
2F:
The capstan servo locks every two fields regardless of the setting of the
function menu item CAPSTN.
4F:
The capstan servo locks every four fields regardless of the setting of the
function menu item CAPSTN.
8F (For 50i, 25PsF mode only):
The capstan servo locks every eight fields
regardless of the setting of the function menu item CAPSTN.
Note
When operating in 24PsF or 23.98PsF mode, the setting is 2F and this item is not
displayed.
(Continued)
CAPSTAN LOCK
In the “Settings” column of the table, the factory
default settings are underlined.
107
REC INHIBIT LAMP
FLASHING
Select whether or not to flash the REC INHI indicator when the function menu
item RECINH is set to OFF and the record inhibit plug on the cassette is pressed
in.
OFF :
Do not flash the REC INHI indicator.
ON:
Flash the REC INHI indicator.
Menu items in the range 100 to 199, relating to the control panels