1-10
VPL-ES7
1-4. 3D GAMMA Service Tool Application Software
Feature:
The Ernie Service Tool is the application software for performing the tasks such as reading out and writ-
ing of the 3D GAMMA data on the projector that is connected to a PC via a communication function.
The Ernie Service Tool has the following features.
.
It can read 3D GAMMA data from a set and save it in a
fi
le.
.
It can write 3D GAMMA data in a PC into a set.
When the optical unit is replaced, write 3D GAMMA data recorded on the CD-ROM, which is supplied
together with the optical unit, into a set using the application software.
.
VPL-ES7 set has not RS-232C terminal, use the QUICK ACCESS Assy.
.
Remove the rubber cap on the upper left of the rear side of the unit.
1-5. Indicator
The error status of the this units are indicated by the type of
fl
ashing of indicator. The top cover has the
ON/STANDBY indicator and the LAMP/COVER indicator. Various error contents are indicated by the
type of
fl
ashing of indicator. For details of the types of indicator
fl
ashing and the error statuses, refer to
the list shown below.
ON/STANDBY Indicator (Red
fl
ashing)
LAMP/COVER Indicator (Orange
fl
ashing)
J12
Set
Main board CN
CN 5P
CN J8
5pin
Dsub
9pin
(Parts No. A-1568-125-A)
RS-232C
Straight
cable
PC
QUICK ACCESS Assy
QUICK ACCESS
Assy
ON
Flash Frequency
Temperature Error
Error Name
Fan Error
Power Error
The temperature of the equipment is high.
Status
Each fan dose not work normally.
The power is not turned on correctly.
2 Times
4 Times
6 Times
OFF
ON
OFF
ON
OFF
Cover Error
Lamp Error
Flash Frequency
Error Name
Status
The lamp or filter cover is opened.
The UHP lamp is not lighting.
2 Times
3 Times
ON
OFF
ON
OFF