1-8
VPL-ES7
1-3-9. Lamp Power Supply
Fan (Exhaust)
80*25
AD0812HB/HB
(Refer to section 1-3-8, steps 2 to 8.)
Lamp box assembly
Lamp nozzle assembly
Focus/Zoom adjust
assembly
Optical unit assembly
(Refer to section 1-3-6, steps 5 to 9) and
(refer to section 1-3-7, steps 1 to 6.)
Route the harness
through the hole of
this sheet.
Caution :
When re-assembling the machine,
route the respective harnesses and
wires at the specified locations as shown.
Lamp power supply
Door detection switch board
Route the Lamp connector
assembly
between them.
Two tapping screws
(PAN
M3
x
7)
Remove the lamp power supply
in the direction of the arrow
.
Claw
Door detection
switch
board
Two harnesses
Door detection
switch board
CN1
X1
Lamp power supply
Lamp power supply
Lamp connector
assembly
Mylar ballast
Mylar ballast