5-16
1-2-14. IRIS IN/OUT Adjustment
Purpose:
Measure the light level and write into
EEPROM for indoor/outdoor identification in
auto white balance.
Adjustment error:
Incorrect white balance.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display on the EVF or monitor
Measuring Instrument
TV, or the page A data display on the
adjustment remote commander.
Adjustment Page
F
Adjustment Address
36, 37
Adjustment procedure:
Note 2:
The lower 4 digit data shown on the right bottom of EVF
or monitor display. If the values in the lower digit change
rapidly and cannot read it, record the data on tape once.
Play it back in STILL mode and take an average value.
Processing after Adjustments:
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data. (Preparation 1)
2
D
11
02
After setting the data, press the PAUSE button.
3
6
00
01
Set the data. (Preparation 2)
4
6
04
06
Set the data.
5
6
40
02
After setting the data, press the PAUSE button.
6
6
01
0B
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 2), or the display data of page A on the adjustment remote commander
(Note 3). The upper 2 digits are D
1
data while the lower 2 digits are D
2
.
7
Convert the data D
1
into the decimal numbers. The result decimal number is D
1
'
(Use page 5-73 “Hexadecimal-Decimal Conversion Table”.)
8
Calculate the following equation (decimal number calculation) to obtain D
3
'.
When D
2
D0h,
D
3
' = D
1
' – 21 ····························· equation 1.
When D
2
< D0h,
D
3
' = D
1
' – 22 ····························· equation 2.
9
Convert the decimal number D
3
' to the hexadecimal number to obtain D
3
.
10
F
36
Set the data D
3
(obtained at step 9), and press the PAUSE button.
11
6
01
09
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 2), or the display data of page A on the adjustment remote commander
(Note 3). The uppers 2 digits are D
4
data while the lower 2 digits are D
5
.
12
Convert the data D
4
into the decimal numbers. The result decimal number is D
4
'
(Use page 5-73 “Hexadecimal-Decimal Conversion Table”.)
13
Calculate the following equation (decimal number calculation) to obtain D
6
'
When D
5
F0h,
D
6
' = D
4
' – 13 ····························· equation 3.
When D
5
< F0h,
D
6
' = D
4
' – 14 ····························· equation 4.
14
Convert the decimal number D
6
' to the hexadecimal number to obtain D
6
.
15
F
37
Set data D
6
(obtained at step 14), and press the PAUSE button.
Note 3:
The 4 digit data display on page : A of adjustment remote
commander.
A :
XX : XX
Lower 2 digits
Upper 2 digits
Note 1:
Set the STEADY SHOT switch (MENU display) to OFF
and the D ZOOM (MENU display) to OFF.
Order
Page
Address
Data
Procedure
1
6
01
00
After setting the data, press the PAUSE button.
2
6
40
00
After setting the data, press the PAUSE button.
3
6
04
00
Set the data.
4
6
00
00
Set the data. (End 2)
5
D
11
00
After setting the data, press the PAUSE button.
6
0
01
00
Set the data. (End 1)
Содержание Handycam DCR-PC10
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 45: ...DCR PC10 PC10E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 46: ...DCR PC10 PC10E 3 2 POWER SUPPLY BLOCK DIAGRAM 3 6 3 7 3 8 3 9 3 10E ...
Страница 76: ...DCR PC10 PC10E DD 103 I O SCHEMATIC DIAGRAM Ref No DD 103 board 30 000 series I O DD 103 2 2 4 102 4 103 4 104 ...