5-48
2. PLL fo Adjustment (MR-39 Board)
Mode
VTR stop
Measurement Point
The displayed data of address : 04 on
Measuring Instrument
page : 3
Adjustment Page
C
Adjustment Address
3D, 3C
Specification Value
The displayed data is in the range
from FD to FF, or in the range from
00 to 03.
(FF and 00 are the center values.)
Adjustment procedure:
Processing after Adjustments:
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data. (Preparation)
2
3
01
05
After setting the data, press the PAUSE button.
3
3
36
04
After setting the data, press the PAUSE button.
4
3
04
Take reading of the displayed data of address : 04 on page : 3 several times and take the
average value which is taken as D
04
. Confirm that D
04
is in the range from “FD” to “FF” or
from “00” to “03”.
5
C
3C
If D
04
is not in the specified range in step 4, adjust the data of address : 3C on page : C as
follows and check the result again.
[When D
04
is in the range from 80 to FC]
Decrease the data of address : 3C on page : C.
(To write the data, press the PAUSE button of the adjustment remote commander after data
is changed.)
[When D
04
is in the range from 04 to 7F]
Increase the data of address : 3C on page : C.
(To write the data, press the PAUSE button of the adjustment remote commander after data
is changed.)
6
3
36
05
After setting the data, press the PAUSE button.
7
3
04
Confirm that the average data D
04
of address : 04 on page : 3 is in the range from “FD” to
“FF” or from “00” to “03”.
8
C
3D
If D
04
is not in the specified range in step 7, adjust the data of address : 3D on page : C as
follows and check the result again.
[When D
04
is in the range from 80 to FC]
Decrease the data of address : 3D on page : C.
(To write the data, press the PAUSE button of the adjustment remote commander after data
is changed.)
[When D
04
is in the range from 04 to 7F]
Increase the data of address : 3D on page : C.
(To write the data, press the PAUSE button of the adjustment remote commander after data
is changed.)
Order
Page
Address
Data
Procedure
1
3
36
02
After setting the data, press the PAUSE button.
2
3
01
00
After setting the data, press the PAUSE button.
3
0
01
00
Set the data. (End)
Содержание Handycam DCR-PC10
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 45: ...DCR PC10 PC10E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 46: ...DCR PC10 PC10E 3 2 POWER SUPPLY BLOCK DIAGRAM 3 6 3 7 3 8 3 9 3 10E ...
Страница 76: ...DCR PC10 PC10E DD 103 I O SCHEMATIC DIAGRAM Ref No DD 103 board 30 000 series I O DD 103 2 2 4 102 4 103 4 104 ...