5-55
3-5-3.
Clock Adjustment
1. IC1900 27MHz XTAL fo adjustment (VC-199 Board)
Set the sub-carrier frequency of the video output signal in VTR
mode.
Mode
VTR stop
Signal
No signal
Measurement Point
R1901 (Pin
2
of IC1900)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
98
Specified Value
f = 13500000 ± 50 Hz (NTSC)
f = 13500000 ± 50 Hz (PAL)
Adjustment procedure:
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data. (Preparation)
2
D
98
Change the data until the clock frequency (f) satisfies the specification value.
3
Press the PAUSE button.
4
0
01
00
Set the data. (End)
Содержание Handycam DCR-PC10
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 45: ...DCR PC10 PC10E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 46: ...DCR PC10 PC10E 3 2 POWER SUPPLY BLOCK DIAGRAM 3 6 3 7 3 8 3 9 3 10E ...
Страница 76: ...DCR PC10 PC10E DD 103 I O SCHEMATIC DIAGRAM Ref No DD 103 board 30 000 series I O DD 103 2 2 4 102 4 103 4 104 ...