Purpose of this manual

This is the Installation Manual of Hybrid Network Fileserver FSV-VN7/CS7.
This manual describes the information items that premise the service based on the

components parts such as introduction, tool and measuring instruments, installation
procedure, troubleshooting, assuming use of system and service engineers.

Related manuals

Besides this “Installation Manual”, the following manuals are available.

• Administrator’s Guide (Supplied with this unit.)

This manual is necessary for application and operation of this unit.
Part number: 3-991-690-XX

Manual Structure

Содержание FSV-CS7

Страница 1: ...HYBRID NETWORK FILESERVER FSV VN7 FSV CS7 INSTALLATION MANUAL 1st Edition ...

Страница 2: ...erden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de ré...

Страница 3: ...7 Main Server 3 6 3 2 5 FSV CS7 Cache Server 3 8 3 3 Library Configuration 3 9 3 3 1 License Registration 3 9 3 3 2 Verification of Library Connection 3 9 3 3 3 Verification of Firmware Revision 3 10 3 4 System Settings 3 11 3 4 1 Main Server Time Setting 3 11 3 4 2 NTP Setting 3 12 3 4 3 Cache Server Time Settings 3 12 3 5 Volume Registration 3 12 3 5 1 Start up 3 12 3 5 2 Volume Registration 3 1...

Страница 4: ...components parts such as introduction tool and measuring instruments installation procedure troubleshooting assuming use of system and service engineers Related manuals Besides this Installation Manual the following manuals are available Administrator s Guide Supplied with this unit This manual is necessary for application and operation of this unit Part number 3 991 690 XX Manual Structure ...

Страница 5: ...an extend 8 units of FSV CS7 Cache Server and up to 4 units of LIB 162 A3 A4 AIT Library or up to 2 units of CSM 20 SAIT Library to meet the customer s requirement The detail of connection is described in Section 3 1 Configuration This system is a hybrid NAS Network Attached Storage device that is composed of a main server a cache server an AIT Library and a SAIT Library into an integrated storage...

Страница 6: ...this system Management Software Basic System Option units Cleaning Tape Application Server Cache Server Cache Server Switching Hub Main Server SAIT Library SAIT Library Administrator s Computer Web Administration Screen Existing LAN System Example with SAIT Libraries CSM 20 ...

Страница 7: ...dia 15 tapes for each AIT Library SDX4 200C AIT4 data media Mix of AIT3 and AIT4 is not allowed in one library Cleaning Tape One for each AIT Library SDX1 CL for AIT3 drives It needs to be a specified model to the SDX4 CL for AIT4 drives library type Cleaning tape One tape for each SAIT Library SAIT1 CL for SAIT1 drives 19 Mount Kit ACY RK2 1 193 001 thru 1 203 000 For LIB 162 AIT Library 19 Mount...

Страница 8: ......

Страница 9: ...s list Tools whose names are displayed in blue have hyper link to the details of the specification You may be able to get the equivalent one in your market Description SONY Parts No Remarks Torque Drivers and Bits for assembly assembly and disassembly Notebook PC Ethernet Cable Cat5 Network Cable At least 1 5 m length USB keyboard VGA Display Section 2 Tool and Measuring Instruments ...

Страница 10: ......

Страница 11: ...ing 3 3 Library Configuration 3 4 System settings 3 5 Volume Registration 3 6 Final Verification 3 1 1 Prior to Connecting 3 1 2 Configuration 3 2 2 CSM 20 SAIT Library 3 2 3 Your PC for webmin Access 3 2 1 LIB 162 AIT Library 3 2 4 FSV VN7 Main Server 3 3 1 Licence Registration 3 3 2 Verification of Library connection 3 4 1 Main Server time setting 3 4 2 NTP setting 3 4 3 Cache Server time settin...

Страница 12: ...to the customer s network 2 The LAN3 port should be used to connect to the Cache Server through the Switching HUB 3 Connect a keyboard to the Main Server and the Cache Server via the PS 2 port respectively 4 Connect the AIT Library ies or the SAIT Library ies with SCSI cable s as follows 5 Connect a terminator LIB 162 accessory PN 1 794 041 51 to the empty SCSI connector on the back of the AIT Lib...

Страница 13: ...B Power Cable Power Cable Not used Power Cable Keyboard for Service Keyboard for Service User LAN Main Server Cache Server Network Cable straight Network Cable straight Network Cable straight Basic System Service Note PC Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Option Unit Not used Cache Server Cache Server Cache ...

Страница 14: ...ard for Service User LAN Main Server Cache Server Network Cable straight Network Cable straight Network Cable straight Basic System Service Note PC Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Not used Power Cable Option Unit Not used SCSI Cable Terminator Power Cable Not used SCSI Cable Power Cable Not used Cache Server Cache Server Cach...

Страница 15: ...e2 12 n Libraries are assigned from the lowest SCSI ID first to match on display of Management software windows but SCSI ID 7 is already reserved for the Main Server 3 2 2 CSM 20 SAIT Library Before setting up read the Instruction Manual for each library Connect the Main Server and the SAIT Libraries with SCSI cables Leave them ready for use Assign the SCSI ID as shown below Description SAIT Libra...

Страница 16: ...n should pop up enter sony for User name sony2002 for Password Click the Login button 2 Licence agreement at the first login to the HNF Show the licence agreement to the customer then go to next step If failed to show it to the customer it can be re displayed anytime Refer to 5 1 License Agreement 3 Overview of Webmin When Login is successful the following window appears 3 2 3 Your PC for Webmin A...

Страница 17: ...g dos charset to a code other than CP932 set unix charset and display charset to UTF8 Language Code Table Language Code USA CP437 Greek CP737 Western European CP850 MS DOS Latin 2 CP852 Icelandic CP861 Cyrillic CP866 Kanji SJIS default CP932 Simplified Chinese CP936 Hangul CP949 Traditional Chinese CP950 5 Network Setup n Do not use setup and netconfig command of the Main Server to change the netw...

Страница 18: ... command The Default address used on the Cache Server is 192 168 1 128 Sonycache xxx xxx x xxx x x x x 4 Configuration of the Cache Server Select the Setup Cache Configuration icon When the Cache Search button is pressed when the connected cache is displayed press the Add Cache button If not type the cache IP address in the Host column In the cache name column re write the X part of CX as the cach...

Страница 19: ...yed In this case check if the value is properly typed in Refer to Section 4 3 3 2 Verification of Library Connection Click on the Setup Library Configuration icon The window shows the case of the CSM 20 SAIT Library When a Library with two AIT drives is connected success fully all the devices should be displayed as shown in the example above Check the Device List status and click on the run librar...

Страница 20: ...rsion is old a recommended version is suggested in red A procedure for version up is following http bay99 ts strg sony co jp index php Process Stop PetaServe service Webmin Services Start Stop of PetaServe Upgrade the firmware by the menu Webmin Services Firmware Revisions Check the firmware if it is same as the recommended version If not the Update icon should be high lighted If it is grayed out ...

Страница 21: ...ing the time zone reset the system setting Login the Main Server and execute the following command sed e s UTC UTC true etc sysconfig clock tmp clock mv tmp clock etc sysconfig clock c Do not set the Timezone by using the setup command It may result in an incorrect setting Do not change the Timezone on the Cache Servers When the Cache Server needs time settings go to 3 4 3 Cache Server time settin...

Страница 22: ... less than 1000 seconds When time difference is more then 1000 seconds set the Cache Server time as follows date MMDDhhmmYY Example 2004 03 07 15 12 date 0307151204 n Do not change the Timezone on the Caches Server s When using the date command use GMT Greenwich Mean Time conversion and set the date and time 3 5 Volume Registration 3 5 1 Start up Verify the hardware main server cache server and ta...

Страница 23: ... Volume Maintenance icon In case of the LIB 162 2 Click the Stop Quiesce Library button 3 After the library is stopped insert a cleaning tape to the slot 16 of the Library n Do not insert a data tape to slot 16 as the slot 16 is reserved for a cleaning tape If a data tape is inserted to this slot the tape can not be recognized 4 Insert 15 tapes into the slot 1 to 15 of the library If time does not...

Страница 24: ...ase of the CSM 20 2 Insert a cleaning tape in the slot 14 n Do not insert a data tape to slot 14 as the slot 14 is reserved for a cleaning tape If a data tape is inserted to this slot the tape can not be recognized 3 Insert 19 tapes in the slots 1 to 13 and 15 to 20 of SAIT library If time does not permit insert at least 4 tapes 4 Click the New Volume Insert button to insert a volume in the mail s...

Страница 25: ...tor are in good condition Read each message carefully to reconfirm that there is no problem and delete them If the migration and reload test described in 3 6 4 are successful the system should be no problem 3 6 2 Mount 1 An example of NFS Mount Follow the steps below to mount the MFS partition as NFS 1 Login as root 2 Create a mount point mkdir hnf1 3 Mount an MFS partition like following The glob...

Страница 26: ...imeout value When a setup file is created with the default timeout value the timeout is set to 600 seconds Click Creates a file for registry configuration button Right click on the DOWNLOAD stimeout600reg And then following window will appear Click Open button Click Yes button Apply the registry change a reboot will be required for the changes to take effect On the client side the default CIFS mou...

Страница 27: ...3 15 223 195 mfs2 Login as mfs and password is sonyhnf to mount the file system When a new drive appears Mount is completed 3 6 3 Alert Mail Verify that the mail outputting and transmission is correct as follows 1 Verify that the Alert mail setting is completed 2 Input the following command osmlogger m testlevel l L 3 Confirm that a test Alert message GEN0102 0001 appears and a mail is sent from t...

Страница 28: ...he and a tape This condition is called shadowed root sonyhnf TL1 migreload test root sonyhnf TL1 migls test size sgrp file 102400 group1 test 6 If sgrp is group1 and the file name is displayed without the reloading is completed 7 Input the following commands to perform migration once again root sonyhnf TL1 migrate f test root sonyhnf TL1 migls test 8 The file is migrated and the symbol is added to...

Страница 29: ...brary is under operation the operating state is displayed on the lower line of the LCD panel display such as FROM TO or Please Wait After turning off the S AIT library wait at least 10 seconds before turning it on again 3 6 6 Restart of the HNF System Turn on the units with the following order for more details refer to 3 2 Setting AIT Library ies or SAIT Library ies Cache Server s Main Server 3 6 ...

Страница 30: ...vailable automatically with the default setting When the residual power capacity goes below 5 or less than three minutes the UPS shuts the system down automatically For more information refer to the UPS operation manual 3 8 UPS Setting Setting of the UPS enable disable is available with HNF V1 30 or later Choose Setup Software Configuration to open the following window To enable the UPS check the ...

Страница 31: ...orking properly Reboot the Cache Server IP address is incorrect or duplicated Input a correct IP address Serial or Code is incorrect on the License List Input a correct value Licence is not registered or incorrect Check the FZL V16AL and register a Licence A Licence is not registered or incorrect Check the FZL V16AL and register a Licence 1 Device identification failed 2 Reload the browser softwar...

Страница 32: ... Cache Server manually and try shutdown again 2 If still unsuccessful connect a terminal display and check the console messages 3 If still unsuccessful reboot the Main Server forcibly When the Main Server OS wonÅft start up 1 Check the console messages by connecting a terminal display 2 Check the SCSI connection and reboot the Library then reboot the Server later When the PetaServe service won t s...

Страница 33: ...nd Line After rebooting the Server connect a terminal display and login as root with password sony2002 Then edit the configuration file by a text editor manually like below etc sysconfig network scripts ifcfg bond0 DEVICE bond0 IPADDR 43 15 223 196 NETMASK 255 255 255 0 ONBOOT yes BOOTPROTO none USERCTL no BROADCAST 43 15 223 255 NETWORK 43 15 223 0 GATEWAY 43 15 223 254 To enable the changes perf...

Страница 34: ......

Страница 35: ...é de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich...

Страница 36: ...Printed in Japan Sony Corporation 2006 5 08 2006 FSV VN7 SYL FSV CS7 SYL E 9 968 286 01 ...

Отзывы: