4-12. VTR/BIN UNIT INSTALLATION (FOR DVCAM)
4-12-1. Installing the Rack Mount Kit and VTR
Preliminary Information
.
A maximum of nine VTRs and bin units in all can be mounted
when the DVCAM VTR is installed in the BFC-1. Select a
proper combination according to the operation conditions of the
user.
Twenty-one volumes of DV cassettes can be stored for each DV
cassette bin unit BKFC-21DV.
.
The VTR can be pulled out from the front or rear of a cart ma-
chine by changing how to install the rack mount kit.
Display the type as [front drawer] if you want to pull out the
VTR from the front.
[FRONT|DRAWING]
Display the type as [rear drawer] if you want to pull out the
VTR from the rear. Each installation method is described in this
case.
[REAR|DRAWING]
.
Remove the legs of the VTR to be installed in advance.
.
The flowchart below shows the installation procedure of a rack
mount kit on one side. The installation of a rack mount kit on
the other side is also the same as the procedure below. (The fol-
lowing flowchart is explained based on a front drawer type.)
Flowchart for rack mounting procedure.
DVCAM
FEET
Start
Disassemble rack mount kit.
Install rail fixing plate assembly.
(VTR side)
Install VTR.
Install shutter plate and adjust height.
End
(Cart machine side)
Install outer rail.
Install reference plates.
Install reference pins.
Remodel hand.
VTR
DVCAM
Rack
Mount Kit
BKFC-54
BKFC-21DV
BIN Unit
BKFC-210
HAND Kit
Note :
Prepare BKFC-54 having a product code ending with
-1 or higher when installing the DSR-1600/1800 series
VTRs.
.