– 8 –
MVC-FD100/FD100H/FD200/FD200H
[Description on Self-diagnosis Display]
Note :
The “Self-diagnosis” data is backed up by the coin lithiumbattery.
The data will be lost and initialized when the coin lithium battery
is removed.
Display Code
C:32:01
C:13:01
E:91:01
E:61:00
E61:10
Countermeasure
Change the disk and turn off the main
power then back on.
Replace the floppy disk or “Memory
Stick”.
Format the floppy disk or “Memory
Stick” with the MVC-FD100/FD200.
Checking of flash unit or replacement of
flash unit
Checking of lens drive circuit
Cause
Defective floppy disk.
• The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
• Data is damaged.
• Unformatted disk or “Memory Stick”
is inserted.
Abnormality when flash is being
charged.
When failed in the focus initialization.
Caution Display During Error
DRIVE ERROR
DISK ERROR
MEMORY STICK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
—
Note :
The error code is cleared if the battery is removed, except defective flash, unit.
*1: When the flash charging failed, Page: D, Address: 67, Data: 04 are written.
After repair, be sure to write Page: D, Address: 67, Data: 00.
[Power supplying Method]
Use the AC power adaptor (AC-L10A) when supplying the power to this set.
*1