– 6 –
MVC-FD100/FD100H/FD200/FD200H
[Discharging of the FLASH unit’s charging capacitor]
The charging capacitor of the FLASH unit is charged up to the
maximum 300 V potential.
There is a danger of electric shock by this high voltage when the
battery is handled by hand. The electric shock is caused by the
charged voltage which is kept without discharging when the main
power of the MVC-FD100/FD200 is simply turned off. There-
fore, the remaining voltage must be discharged as described be-
low.
Preparing the Short Jig
To preparing the short jig. a small clip is attached to each end of a
resistor of 1 k
Ω
/1 W (1-215-869-11).
Wrap insulating tape fully around the leads of the resistor to pre-
vent electrical shock.
1 k
Ω
/1 W
Wrap insulating tape.
Discharging the Capacitor
Short-circuit between the positive and the negative terminals of
charged capacitor with the short jig about 10 seconds.
SERVICE NOTE
•
NOTE FOR REPAIR
Make sure that the flat cable and flexible board are not cracked of
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
When remove a connector, don’t pull at wire of connector.
It is possible that a wire is snapped.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some pieces of
gilt may be left inside)
When installing a connector, don’t press down at wire of connector.
It is possible that a wire is snapped.
Capacitor
R: 1 k
Ω
/1 W
(Part code:
1-215-869-11)
Содержание FD Mavica MVC-FD100
Страница 71: ...5 1 MVC FD100 FD100H FD200 FD200H SECTION 5 ADJUSTMENTS ...
Страница 130: ... 152 MVC FD100 FD100H FD200 FD200H Sony EMCS Co 9 929 934 31 2003I0500 1 2003 9 Published by DI CS Strategy Div ...
Страница 150: ... 28 MVC FD100 FD100H FD200 FD200H Sony EMCS Co 9 929 934 83 2003E0500 1 2003 5 Published by DI Customer Center ...