5-32
MVC-FD100/FD100H/FD200/FD200H
17. Strobe White Balance Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(1 m from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: 64
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69 to 6B
Specified Value
Y level data: 60 to 94 (Note 5)
R-Y level data:
FA to FF or 00 to 06 (Note 4)
B-Y level data:
FA to FF or 00 to 06 (Note 4)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Do not block the photocell window for flash.
Restrict external light to enter the photocell window for
flash as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 5-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
B-Y level data
R-Y level data
Note 5:
Displayed data of page: F, address: 64 of the adjusting
remote commander.
F:XX:64
Y level data
Note 6:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-16)
2
6
90
00
3
6
91
00
4
6
92
FF
5
6
93
FF
6
6
6C
01
7
6
2C
01
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
67
Press PAUSE button.
11
Check the flashing.
12
6
02
Check the data changes to “01”.
13
6
01
00
Press PAUSE button.
14
6
01
67
Press PAUSE button.
15
Check the flashing.
Order Page Address Data
Procedure
16
6
02
Check the data changes to “01”.
17
6
01
00
Press PAUSE button.
18
7
03
05
Press PAUSE button.
FD100: TYPE SO only (Note 8)
19
6
01
B9
Press PAUSE button. (Note 7)
20
Check the flashing.
21
6
02
Check the data changes to “01”.
22
Wait for 3 seconds.
23
6
01
00
Press PAUSE button.
24
7
03
04
Press PAUSE button.
FD100: TYPE SO only (Note 8)
25
6
01
67
Press PAUSE button.
26
Check the flashing.
27
6
02
Check the data changes to “01”.
28
F
64
Check that the data satisfies
the Y level data satisfied
value. (Note 5)
29
0
03
02
30
1
Check that the R-Y, B-Y
level data (Note 4) satisfies
the specified value.
Note 7:
The adjustment data will be automatically input to page:
F, address: 4D, 4E, 64 and 69 to 6B.
Note 8:
Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
6C
00
4
6
92
00
5
6
93
00
6
0
03
00
7
Release the data setting
performed at step 1.
(Refer to page 5-16)
Содержание FD Mavica MVC-FD100
Страница 71: ...5 1 MVC FD100 FD100H FD200 FD200H SECTION 5 ADJUSTMENTS ...
Страница 130: ... 152 MVC FD100 FD100H FD200 FD200H Sony EMCS Co 9 929 934 31 2003I0500 1 2003 9 Published by DI CS Strategy Div ...
Страница 150: ... 28 MVC FD100 FD100H FD200 FD200H Sony EMCS Co 9 929 934 83 2003E0500 1 2003 5 Published by DI Customer Center ...