2-7
SNC-CS20/CM120
2-2-7. Mechanical Iris Adjustment
.
Subject:
Gray scale chart type I
.
Measuring equipment: None
.
Specification:
None
1.
Shoot the Gray scale chart type I using this unit and
adjust the angle of view.
2.
Click the
[Adjust|DC|Servo|Lens]
button.
3.
Check that “OK” is displayed in the upper right area of
the window, and then click the
[Next]
button.
2-2-8. Video Level Adjustment
.
Subject:
Clear chart
.
Measuring equipment: Waveform monitor
.
Specification:
NTSC: C = 65
±
5 (IRE)
PAL:
C = 455
±
35 (mV)
1.
Shoot the clear chart and adjust the angle of view.
2.
Operate the spin box while checking the waveform
monitor to adjust the level to the specification C.
3.
Click the
[OK]
button.
4.
Check that “OK” is displayed in the upper right area of
the window, and then click the
[Next]
button.
SNC
_
CM120
SNC
_
CM120
SNC
_
CM120
C
Spin box
SNC
_
CM120
Содержание EXWAVEPRO SNC-CM120
Страница 1: ...NETWORK CAMERA SNC CS20 SNC CM120 SERVICE MANUAL 1st Edition ...
Страница 4: ......
Страница 6: ......
Страница 14: ......
Страница 28: ......
Страница 42: ......
Страница 58: ......
Страница 61: ...SNC CS20 CM120 Appendix DIAMETER 80 mm DIAMETER 106 mm SNC CS20 DIAMETER 80 mm DIAMETER 106 mm SNC CM120 ...
Страница 62: ......
Страница 63: ......
Страница 64: ...Printed in Japan Sony Corporation 2008 7 22 2008 SNC CS20 SY SNC CM120 SY E 9 968 462 01 ...