![Sony EXWAVEPRO SNC-CM120 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/sony/exwavepro-snc-cm120/exwavepro-snc-cm120_service-manual_417981018.webp)
2-4
SNC-CS20/CM120
2.
Operate the spin box so that the voltage value of the
voltmeter matches the value displayed in the lower
area of the adjustment software window.
3.
Click the
[OK]
button.
4.
Check that “OK” is displayed in the upper right area of
the window, and then click the
[Next]
button.
Spin box
6
SNC
_
CM120
SNC
_
CM120
6
2-2-2. VSUB Voltage Adjustment
(Only SNC-CM120)
n
You can check the imprint of CCD used in this adjustment
from the side B of the BI-227 board. Before starting the
procedure, disassemble this unit so that you can check the
BI-227 board and write down the imprinted letter. Be sure
to read the letter from the direction as shown in the picture.
.
Subject:
None
.
Measurement device: Voltmeter
.
Specification:
Displayed in the lower portion of
the adjustment software window.
1.
Select the letter imprinted on the backside of CCD (“f”
in the above picture), then click the
[OK]
button.
Imprinted letter
List box
Specificaion
SNC
_
CM120
6
Содержание EXWAVEPRO SNC-CM120
Страница 1: ...NETWORK CAMERA SNC CS20 SNC CM120 SERVICE MANUAL 1st Edition ...
Страница 4: ......
Страница 6: ......
Страница 14: ......
Страница 28: ......
Страница 42: ......
Страница 58: ......
Страница 61: ...SNC CS20 CM120 Appendix DIAMETER 80 mm DIAMETER 106 mm SNC CS20 DIAMETER 80 mm DIAMETER 106 mm SNC CM120 ...
Страница 62: ......
Страница 63: ......
Страница 64: ...Printed in Japan Sony Corporation 2008 7 22 2008 SNC CS20 SY SNC CM120 SY E 9 968 462 01 ...