3-16
DSR-570WS/570WSP V1
4. Cue Up To Record Start Point
After tape is recorded for about one minute, tape is rewound up to the record start point.
Check is performed during the period from the time when recording is terminated automatically until the tape is rewound
up to the record start point. When any abnormalities are detected, the error code is displayed.
Displays, Error Contents, Measures or Possible Abnormalities
Code
Error contents, measures or possible abnormalities
12
The cassette compartment lock is released.
19
Tape end is detected.
1a
LEDs of the tape top end sensor are abnormal.
21
LED of the mechanical function cam mode sensor is abnormal.
22
LED of the mechanical function cam mode sensor is abnormal.
23
LED of the mechanical function cam mode sensor is abnormal.
24
LED of the mechanical function cam mode sensor is abnormal.
28
The operating voltage/current of the function cam motor is abnormal.
38
The operating voltage/current of the drum motor is abnormal.
48
The operating voltage/current of the capstan motor is abnormal.
50
LED of the supply reel FG sensor is abnormal.
70
LED of the take-up reel FG sensor is abnormal.
98
Operating voltage/current of the reel motor is abnormal.
c1
LED of the reel position (standard cassette position) sensor is abnormal.
c2
LED of the reel position (mini cassette position) sensor is abnormal.
c8
The operating voltage/current of the reel shift motor is abnormal.
Содержание DSR-570WS
Страница 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Страница 14: ......
Страница 18: ......
Страница 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Страница 68: ......
Страница 86: ......
Страница 118: ......
Страница 198: ......
Страница 204: ......
Страница 222: ......
Страница 248: ......
Страница 249: ......
Страница 250: ...Printed in Japan Sony Corporation 2002 1 08 B P Company 2002 DSR 570WS UC DSR 570WSP CE E 9 967 976 01 ...