6-3
DSR-570WS/570WSP V1
Cap (red)
Threading end
Unthreading end
No. 1 gear
1) Setting manually
.
Open the left panel assy.
(Refer to Section 2-2-1.)
.
Rotate the cap and No. 1 gear shown in the
figure in the arrow direction while pressing it
down to set the threading end/unthreading end.
2) Setting with the menu
Select Menu No. 613, and set the function cam
mode.
.
Threading is carried out while the STOP
button is pressed.
.
Unthreading is carried out while the EJECT
button is pressed.
3. Reel Table Position
It is set to the mini cassette position/standard
cassette position according to the position of the
S reel table assembly/T reel table assembly.
Mini cassette position:
The reel lock arm, S reel table assembly/T reel
table assembly, and MIC assembly are
positioned at the drum side as shown in the
figure.
Standard cassette position:
The reel lock arm, S reel table assembly/T reel
table assembly, and MIC assembly are
positioned at the inserting side of the cassette as
shown in the figure.
Mini cassette position
Standard cassette position
S reel table assembly
Reel lock arm
T reel table assembly
MIC assembly
S reel table assembly
Reel lock arm
T reel table assembly
MIC assembly
Содержание DSR-570WS
Страница 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Страница 14: ......
Страница 18: ......
Страница 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Страница 68: ......
Страница 86: ......
Страница 118: ......
Страница 198: ......
Страница 204: ......
Страница 222: ......
Страница 248: ......
Страница 249: ......
Страница 250: ...Printed in Japan Sony Corporation 2002 1 08 B P Company 2002 DSR 570WS UC DSR 570WSP CE E 9 967 976 01 ...