2-37
DSR-570WS/570WSP V1
BP Battery Preset Adjustment 2
1. Set the SYSTEM MENU (refer to Section 4-1-2), and
select the “BP battery preset adjustment 2 mode (Menu
No. 513)” (Refer to Fig. A”).
2. Press the RESET (MENU SET) button to blink the
voltage displayed on the display window (Fig. B”).
Adjust the DC power supply so that the digital
voltmeter shows 13.00 V (Fig. 1).
3. Press the RESET (MENU SET) button to write the set
value in the EEPROM. “YES” will be displayed when
the desired voltage is set (Fig. C”). “no” will be
displayed when an error occurs while writing in the
EEPROM and the value could not be set (Fig. D”). In
this case, repeat steps 1 to 3.
m
.
Set the voltage as 13.00
±
0.01 V.
.
The voltage value shown on the display window is for
reference.
.
If this menu is set by mistake, always press the MENU
button to exit from this menu. Never press the RESET
(MENU SET)button. When pressing the RESET button,
the data being set will be written.
Display window (LCD)
D”
Blinking menu No. (When changed)
Voltage and A/D coversion value can be input
Save NG
C”
Save OK
B”
A”
Содержание DSR-570WS
Страница 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Страница 14: ......
Страница 18: ......
Страница 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Страница 68: ......
Страница 86: ......
Страница 118: ......
Страница 198: ......
Страница 204: ......
Страница 222: ......
Страница 248: ......
Страница 249: ......
Страница 250: ...Printed in Japan Sony Corporation 2002 1 08 B P Company 2002 DSR 570WS UC DSR 570WSP CE E 9 967 976 01 ...